![Omron SYSMAC CJ1W-SCU21-V1 Operation Manual Download Page 182](http://html1.mh-extra.com/html/omron/sysmac-cj1w-scu21-v1/sysmac-cj1w-scu21-v1_operation-manual_743586182.webp)
153
Setup Area Allocations
Section 5-2
5-2
Setup Area Allocations
This section explains the Setup Area allocated in the DM Area when a Serial
Communications Board or a Serial Communications Unit is used in protocol
macro mode.
5-2-1
Setup Area Words
The Serial Communications Board and Serial Communications Units use the
following words as a Setup Area in the DM Area when Protocol Macros are
used. The words allocated to the Serial Communications Board are different
from those allocated to the Serial Communications Units (which are allocated
words according to unit numbers).
Serial Communications
Boards (CS Series Only)
Setup Area Allocated in the DM Area:
D32000 to D32099
Serial Communications
Units (CS/CJ Series)
Setup Area Allocated in the DM Area:
D30000 to D31599
First Word in Setup Area Allocated in the DM Area:
m = 100
×
unit number
Words
Usage
D32000 to D32001
D32008 to D32009
Port 1 Settings
D32010 to D32011
D32018 to D32019
Port 2 Settings
D32002 to D32007
D32012 to D32017
Not used with the protocol macro mode
D32020 to D32767
Reserved for the system
Unit No.
DM Area
Unit No. 0
D30000 to D30099
Unit No. 1
D30100 to D30199
Unit No. 2
D30200 to D30299
Unit No. 3
D30300 to D30399
Unit No. 4
D30400 to D30499
Unit No. 5
D30500 to D30599
Unit No. 6
D30600 to D30699
Unit No. 7
D30700 to D30799
Unit No. 8
D30800 to D30899
Unit No. 9
D30900 to D30999
Unit No. A
D31000 to D31099
Unit No. B
D31100 to D31199
Unit No. C
D31200 to D31299
Unit No. D
D31300 to D31399
Unit No. E
D31400 to D31499
Unit No. F
D31500 to D31599
m to m + 1, m + 8 to m + 9: Port 1 Settings
m + 10 to m + 11, m + 18 to m + 19: Port 2 Settings
m + 2 to m + 7, m + 12 to m + 17: Not used
m + 20 to m + 99: Not used
Summary of Contents for SYSMAC CJ1W-SCU21-V1
Page 3: ...iv...
Page 5: ...vi...
Page 9: ...x...
Page 15: ...xvi...
Page 89: ...60 Basic Operating Procedure Section 1 9...
Page 151: ...122 RS 232C and RS 422A 485 Wiring Section 3 4...
Page 173: ...144 Host Link Function for Replacing Existing PLCs Section 4 6...
Page 223: ...194 Enhanced Protocol Macro Functions Section 5 6...
Page 277: ...248 Communications Frames Section 6 8...
Page 291: ...262 Basic Operating Procedure in No protocol Mode Section 7 4...
Page 301: ...272 Auxiliary Area and CIO Area Allocations Section 8 3...
Page 391: ...362 Introduction Appendix A...
Page 421: ...392 CompoWay F Master Protocol Appendix B...
Page 513: ...484 E5 K Digital Controller Read Protocol Appendix F...
Page 571: ...542 E5ZE Temperature Controller Write Protocol Appendix I...
Page 587: ...558 E5 J Temperature Controller Protocol Appendix J...
Page 627: ...598 ES100 Digital Controller Protocol Appendix K...
Page 661: ...632 V500 V520 Bar Code Reader Protocol Appendix M...
Page 697: ...668 3Z4L Laser Micrometer Protocol Appendix N...
Page 717: ...688 Visual Inspection System Protocol Appendix O...
Page 755: ...726 V600 V620 ID Controller Protocol Appendix P...
Page 763: ...734 Hayes Modem AT Command Protocol Appendix Q...
Page 767: ...738 Changing Communications Port Settings Using STUP 237 Appendix R...
Page 781: ...752 Revision History...