V600/V620 ID Controller Protocol
Appendix P
V600-CA
@
A DIP Switches
DIP Switch 1
Mode 1
1 2 3 4 5 6 7 8
Note
1. Data length setting
7 bits: ASCII
8 bits: JIS8 unit code
2. Parity setting
E: Even parity
O: Odd parity
N: No parity designation
•
Baud Rate
Setting
1=ON, 0=OFF
1 = ON, 0 = OFF
Note
Factory Setting: All OFF
SW7 and SW8: Be sure to set to OFF.
•
Communications Format
Baud rate
(bps)
2,400
4,800
9,600
19,200
7
7
7
7
8
8
8
8
2
2
1
1
2
1
1
1
Data
length (bit)
STOP
bit (bit)
Parity type
E
O
O
E
N
O
N
E
1,200
(See note 1)
(See note 2)
DIP Switch 2
Note
1. Be careful not to set to the same unit number twice.
2. Set them to OFF for the 1-to-1 protocol.
•
SW8: Receive Side Terminating Resistance Setting (Valid Only for the V600-CA2A)
1 2 3 4 5 6 7 8
•
SW7: Receive Side Terminating Resistance Setting (Valid Only for the V600-CA2A)
•
SW6: Communications Protocol Setting
•
ID Controller Unit Number Setting (Valid Only for the 1-to-N Protocol)
•
SW1 Setting
This setting is only valid if the EEPROM-type (battery-
less-type) Data Carrier (DC) is accessed. The setting
of SW7 does not work with the SRAM-type (battery-
type) DC.
•
SW6 Setting
When selecting the 1-to-N protocol for the
V600-CA1A/RS-232C interface, the setting is limited
to N=1. In this case, the FCS check code may be add-
ed.
•
Local Communications Mode Setting
Connected (ID Controller send side)
Not connected
Connected (ID Controller receive side)
Not connected
1-to-N protocol
1-to-1 protocol
Unit No.
No. 0
No. 1
No. 2
No. 3
No. 4
No. 5
No. 6
No. 7
No. 8
No. 9
No. 10
No. 11
No. 12
No. 13
No. 14
No. 15
Speed priority setting
Distance priority setting
Summary of Contents for SYSMAC CJ1W-SCU21-V1
Page 3: ...iv...
Page 5: ...vi...
Page 9: ...x...
Page 15: ...xvi...
Page 89: ...60 Basic Operating Procedure Section 1 9...
Page 151: ...122 RS 232C and RS 422A 485 Wiring Section 3 4...
Page 173: ...144 Host Link Function for Replacing Existing PLCs Section 4 6...
Page 223: ...194 Enhanced Protocol Macro Functions Section 5 6...
Page 277: ...248 Communications Frames Section 6 8...
Page 291: ...262 Basic Operating Procedure in No protocol Mode Section 7 4...
Page 301: ...272 Auxiliary Area and CIO Area Allocations Section 8 3...
Page 391: ...362 Introduction Appendix A...
Page 421: ...392 CompoWay F Master Protocol Appendix B...
Page 513: ...484 E5 K Digital Controller Read Protocol Appendix F...
Page 571: ...542 E5ZE Temperature Controller Write Protocol Appendix I...
Page 587: ...558 E5 J Temperature Controller Protocol Appendix J...
Page 627: ...598 ES100 Digital Controller Protocol Appendix K...
Page 661: ...632 V500 V520 Bar Code Reader Protocol Appendix M...
Page 697: ...668 3Z4L Laser Micrometer Protocol Appendix N...
Page 717: ...688 Visual Inspection System Protocol Appendix O...
Page 755: ...726 V600 V620 ID Controller Protocol Appendix P...
Page 763: ...734 Hayes Modem AT Command Protocol Appendix Q...
Page 767: ...738 Changing Communications Port Settings Using STUP 237 Appendix R...
Page 781: ...752 Revision History...