649
3Z4L Laser Micrometer Protocol
Appendix N
Note
This sequence cannot be used to request the lower limit (EL), error upper limit (EH), error exclusion
counter (CNT) of the error data exclusion function (centerless grinder function).
Offset
Contents (data format)
Data
+0
Number of receive data
words (4 digits Hex)
002E (0046 decimal) (fixed)
+1
Program number
(1 digit BCD)
0 to 9
+2 to +4 Segment number
(ASCII 6 characters)
Combination of 31(‘1’) to 36(‘6’), 20(‘ ’)
+5
Measurement interval num-
ber (1 digit BCD)
1 to 4
+6
Lower limit value (Decimal
portion)
(4 digits BCD)
0000 to 9999
+7
Lower limit value (Integer
portion)
(3 digits BCD)
000 to 999
+8
Lower limit value (Sign)
(BIN)
If +: 0
If – : F
+9 to
+11
Upper limit value
Same as lower limit values
+12 to
+14
Multistep selection limit
value (L1)
Same as lower limit values
+15 to
+17
Multistep selection limit
value (L2)
Same as lower limit values
+18 to
+20
Multistep selection limit
value (L3)
Same as lower limit values
+21 to
+23
Multistep selection limit
value (L4)
Same as lower limit values
+24 to
+26
Multistep selection limit
value (L5)
Same as lower limit values
+27 to
+29
Multistep selection limit
value (L6)
Same as lower limit values
+30 to
+32
Reference value
Same as lower limit values
+33
Analog output scale number
(1 digit BCD)
1 to 3
+34 to
+35
Offset classification (ASCII 3
characters)
4F4620 (“OF”), 4F4D20 (“OM”)
+36 to
+38
Offset value
Same as lower limit values
+39
Data output condition
(1 digit BCD)
0 to 6
+40
Scheduled output timer
(3 digits BCD)
000 to 999
+41
Sample measurement pulse
(3 digits BCD)
000 to 999
+42 to
+43
Sample measurement clas-
sification
(ASCII 3 characters)
415647 (“AVG”), 4D4158 (“MAX”)
4D494E (“MIN”), 524E47 (“RNG”)
+44 to
+45
Statistical processing calcu-
lation classification (ASCII 3
characters)
535420 (“ST”), 4E5354 (“NST”)
4 5 6 7
0 1 2 3
F 0 0 0
+6
+7
+8
Example
–123.4567
Summary of Contents for SYSMAC CJ1W-SCU21-V1
Page 3: ...iv...
Page 5: ...vi...
Page 9: ...x...
Page 15: ...xvi...
Page 89: ...60 Basic Operating Procedure Section 1 9...
Page 151: ...122 RS 232C and RS 422A 485 Wiring Section 3 4...
Page 173: ...144 Host Link Function for Replacing Existing PLCs Section 4 6...
Page 223: ...194 Enhanced Protocol Macro Functions Section 5 6...
Page 277: ...248 Communications Frames Section 6 8...
Page 291: ...262 Basic Operating Procedure in No protocol Mode Section 7 4...
Page 301: ...272 Auxiliary Area and CIO Area Allocations Section 8 3...
Page 391: ...362 Introduction Appendix A...
Page 421: ...392 CompoWay F Master Protocol Appendix B...
Page 513: ...484 E5 K Digital Controller Read Protocol Appendix F...
Page 571: ...542 E5ZE Temperature Controller Write Protocol Appendix I...
Page 587: ...558 E5 J Temperature Controller Protocol Appendix J...
Page 627: ...598 ES100 Digital Controller Protocol Appendix K...
Page 661: ...632 V500 V520 Bar Code Reader Protocol Appendix M...
Page 697: ...668 3Z4L Laser Micrometer Protocol Appendix N...
Page 717: ...688 Visual Inspection System Protocol Appendix O...
Page 755: ...726 V600 V620 ID Controller Protocol Appendix P...
Page 763: ...734 Hayes Modem AT Command Protocol Appendix Q...
Page 767: ...738 Changing Communications Port Settings Using STUP 237 Appendix R...
Page 781: ...752 Revision History...