![Omron SYSMAC CJ1W-SCU21-V1 Operation Manual Download Page 98](http://html1.mh-extra.com/html/omron/sysmac-cj1w-scu21-v1/sysmac-cj1w-scu21-v1_operation-manual_743586098.webp)
69
Component Names and Functions
Section 2-1
2-1-3
CJ-series Serial Communications Unit
Indicators
2
ON
4
TERM
ERC
RUN
RD2
SCU41-V1
RD1 TER1
SD2
RDY
NO.
UNIT
ERH
SD1
PORT1
(RS422
/485)
OFF
WIRE
PORT2
01
23
4567
89
AB
CDE
F
ERC
RUN
RD2
SCU21-V1
RD1
SD2
RDY
NO.
UNIT
ERH
SD1
PORT1
PORT2
01
23
4567
89
AB
CDE
F
CJ1W-SCU21-V1
2
ON
4
TERM
ERC
RUN
RD2 TER2
SCU31-V1
RD1 TER1
SD2
RDY
NO.
UNIT
ERH
SD1
PORT1
(RS422
/485)
(RS422
/485)
OFF
WIRE
PORT2
01
23
4567
89
AB
CDE
F
2
ON
4
TERM
OFF
WIRE
CJ1W-SCU41-V1
CJ1W-SCU31-V1
Indicators
Terminating resistance switch
Unit number switch
2-wire/4-wire switch
Port 1: RS-422A/485
Port 2: RS-232C
Indicators
Unit number switch
Port 1: RS-232C
Port 2: RS-232C
Indicators
Unit number switch
Port 1: RS-422A/485
Port 2: RS-422A/485
Terminating resistance
switch (for port 1)
2-wire/4-wire switch
(for port 1)
Terminating resistance
switch (for port 2)
2-wire/4-wire switch
(for port 2)
Magnified view of
bottom-right corner
Indicator
Color
Status
Meaning
RUN
Green
Lit
Operating normally
Not lit
Unit hardware error.
RDY
Green
Lit
Protocol macro preparations have been com-
pleted.
Flashing
Protocol macros are being prepared (see note
1).
Not lit
Hardware error in Serial Communications Unit.
ERH
Red
Lit
CPU Unit error, or this Unit has not been regis-
tered in the I/O table. Routing tables incor-
rectly registered in the Unit.
Flashing
System Setup error (see note 1)
Not lit
CPU Unit is operating normally and the Setup
Area settings are normal.
Summary of Contents for SYSMAC CJ1W-SCU21-V1
Page 3: ...iv...
Page 5: ...vi...
Page 9: ...x...
Page 15: ...xvi...
Page 89: ...60 Basic Operating Procedure Section 1 9...
Page 151: ...122 RS 232C and RS 422A 485 Wiring Section 3 4...
Page 173: ...144 Host Link Function for Replacing Existing PLCs Section 4 6...
Page 223: ...194 Enhanced Protocol Macro Functions Section 5 6...
Page 277: ...248 Communications Frames Section 6 8...
Page 291: ...262 Basic Operating Procedure in No protocol Mode Section 7 4...
Page 301: ...272 Auxiliary Area and CIO Area Allocations Section 8 3...
Page 391: ...362 Introduction Appendix A...
Page 421: ...392 CompoWay F Master Protocol Appendix B...
Page 513: ...484 E5 K Digital Controller Read Protocol Appendix F...
Page 571: ...542 E5ZE Temperature Controller Write Protocol Appendix I...
Page 587: ...558 E5 J Temperature Controller Protocol Appendix J...
Page 627: ...598 ES100 Digital Controller Protocol Appendix K...
Page 661: ...632 V500 V520 Bar Code Reader Protocol Appendix M...
Page 697: ...668 3Z4L Laser Micrometer Protocol Appendix N...
Page 717: ...688 Visual Inspection System Protocol Appendix O...
Page 755: ...726 V600 V620 ID Controller Protocol Appendix P...
Page 763: ...734 Hayes Modem AT Command Protocol Appendix Q...
Page 767: ...738 Changing Communications Port Settings Using STUP 237 Appendix R...
Page 781: ...752 Revision History...