![Omron SYSMAC CJ1W-SCU21-V1 Operation Manual Download Page 691](http://html1.mh-extra.com/html/omron/sysmac-cj1w-scu21-v1/sysmac-cj1w-scu21-v1_operation-manual_743586691.webp)
662
3Z4L Laser Micrometer Protocol
Appendix N
Note
This sequence can be used for the 3Z4L-4000 Series only when pin 8 on DIP switch SW2 is turned ON.
Single Run Measurement Start (4000-series) (Sequence No. 434
(Hex 01B2))
When the sample measurement condition is from 1 to 999, this sequence performs a single run measurement
and requests the measurement results.
Send Data Word Allocation (3rd Operand of PMCR(260))
None.
Receive Data Word Allocation (4th Operand of PMCR(260))
Offset
Contents (data format)
Data
+0
Number of receive data
words (4 digits Hex)
0013 (0019 decimal) (fixed)
+1
Segment number
(1 digit BCD)
1 to 5
+2
Measurement interval num-
ber (1 digit BCD)
1 to 7
+3
Lower limit value (Decimal
portion)
(4 digits BCD)
0000 to 9999
+4
Lower limit value (Integer
portion)
(3 digits BCD)
000 to 999
+5
Lower limit value (Sign)
(BIN)
If +: 0
If –: F
+6 to +8 Upper limit value
Same as lower limit value
+9 to
+11
Reference value
Same as lower limit value
+12
Analog output scale number
(1 digit BCD)
0 to 3
+13 to
+15
Forced zero number (ASCII
5 characters)
5A45524F2B (“ZERO+”)
4E4F524D20 (“NORM ”)
5A45524F2D (“ZERO–”)
+16
Data output condition
(1 digit BCD)
0 to 6
+17
Data output timer value
(3 digits BCD)
000 to 999
+18
Number of seconds for latch
timer
(2 digits BCD)
00 to 99
4 5 6 7
0 1 2 3
F 0 0 0
+3
+4
+5
Example
–123.4567
Receive data
storage words
Number of receive data words
+0
+1
+2
+3
+4
+5
+6
+7
Decimal portion
(Undefined)
Integer portion
Sign
(Undefined)
Decimal portion
(Undefined)
Integer portion
Sign
(Undefined)
Decision result
Measurement value
Deviation value
Summary of Contents for SYSMAC CJ1W-SCU21-V1
Page 3: ...iv...
Page 5: ...vi...
Page 9: ...x...
Page 15: ...xvi...
Page 89: ...60 Basic Operating Procedure Section 1 9...
Page 151: ...122 RS 232C and RS 422A 485 Wiring Section 3 4...
Page 173: ...144 Host Link Function for Replacing Existing PLCs Section 4 6...
Page 223: ...194 Enhanced Protocol Macro Functions Section 5 6...
Page 277: ...248 Communications Frames Section 6 8...
Page 291: ...262 Basic Operating Procedure in No protocol Mode Section 7 4...
Page 301: ...272 Auxiliary Area and CIO Area Allocations Section 8 3...
Page 391: ...362 Introduction Appendix A...
Page 421: ...392 CompoWay F Master Protocol Appendix B...
Page 513: ...484 E5 K Digital Controller Read Protocol Appendix F...
Page 571: ...542 E5ZE Temperature Controller Write Protocol Appendix I...
Page 587: ...558 E5 J Temperature Controller Protocol Appendix J...
Page 627: ...598 ES100 Digital Controller Protocol Appendix K...
Page 661: ...632 V500 V520 Bar Code Reader Protocol Appendix M...
Page 697: ...668 3Z4L Laser Micrometer Protocol Appendix N...
Page 717: ...688 Visual Inspection System Protocol Appendix O...
Page 755: ...726 V600 V620 ID Controller Protocol Appendix P...
Page 763: ...734 Hayes Modem AT Command Protocol Appendix Q...
Page 767: ...738 Changing Communications Port Settings Using STUP 237 Appendix R...
Page 781: ...752 Revision History...