V600/V620 ID Controller Protocol
Appendix P
Write (ASCII/4) (Sequence No. 520 (Hex 0208))
This sequence is used when the number of Heads to be written to the Carrier is 4. Up to 48 bytes of data can
be read for each Read/Write Head.
Send Data Word Allocation (3rd Operand of PMCR(260))
Receive Data Word Allocation (4th Operand of PMCR(260))
None.
Note
Write designated for ASCII is sent beginning with the smallest offset from the send data words.
Offset
Contents (data format)
Data
+0
Number of send data words
(4 digits Hex)
0007 to 0072 (7 to 114 decimal)
+1
Number of Heads
(4 digits BCD)
0001 to 0004
+(28(N–1)+2)
Unit No. (2 digits BCD)
Arbitrary (However, there is a limit for the max-
imum Unit No. depending on the model)
+(28(N–1)+3)
R/W Head CH No.
(1 digit BCD)
R/W Head CH 1 designation: 1
R/W Head CH 2 designation: 2
The CD1D must be set to 1.
+(28(N–1)+4)
Leading address No.
(4 digits Hex)
0000 to FFFF
+(28(N–1)+5)
Number of write bytes
(4 digits Hex)
0001 to 0030 (1 to 48 decimal)
+(28(N–1)+6) to
(28(N–1)+29)
Write data (ASCII)
Input in ASCII.
Up to 48 bytes (max.) can be set
N: Number of Heads
First word of send
data
Number of Heads
+0
+1
+2
+3
+4
+5
+6
+29
+30
+31
+32
+33
+34
+57
+86
+87
+88
+89
+90
+113
CH 1
Number of send data words
(Undefined)
Unit No.
(Undefined)
Head CH No.
Leading address No.
CH 2
Number of write bytes
Write data
~
~
Write data
(Undefined)
Unit No.
(Undefined)
Head CH No.
Leading address No.
Number of write bytes
Write data
~
~
Write data
~
~
(Undefined)
Unit No.
(Undefined)
Head CH No.
Leading address No.
Number of write bytes
Write data
~
~
Write data
CH 4
Summary of Contents for SYSMAC CJ1W-SCU21-V1
Page 3: ...iv...
Page 5: ...vi...
Page 9: ...x...
Page 15: ...xvi...
Page 89: ...60 Basic Operating Procedure Section 1 9...
Page 151: ...122 RS 232C and RS 422A 485 Wiring Section 3 4...
Page 173: ...144 Host Link Function for Replacing Existing PLCs Section 4 6...
Page 223: ...194 Enhanced Protocol Macro Functions Section 5 6...
Page 277: ...248 Communications Frames Section 6 8...
Page 291: ...262 Basic Operating Procedure in No protocol Mode Section 7 4...
Page 301: ...272 Auxiliary Area and CIO Area Allocations Section 8 3...
Page 391: ...362 Introduction Appendix A...
Page 421: ...392 CompoWay F Master Protocol Appendix B...
Page 513: ...484 E5 K Digital Controller Read Protocol Appendix F...
Page 571: ...542 E5ZE Temperature Controller Write Protocol Appendix I...
Page 587: ...558 E5 J Temperature Controller Protocol Appendix J...
Page 627: ...598 ES100 Digital Controller Protocol Appendix K...
Page 661: ...632 V500 V520 Bar Code Reader Protocol Appendix M...
Page 697: ...668 3Z4L Laser Micrometer Protocol Appendix N...
Page 717: ...688 Visual Inspection System Protocol Appendix O...
Page 755: ...726 V600 V620 ID Controller Protocol Appendix P...
Page 763: ...734 Hayes Modem AT Command Protocol Appendix Q...
Page 767: ...738 Changing Communications Port Settings Using STUP 237 Appendix R...
Page 781: ...752 Revision History...