![Omron SYSMAC CJ1W-SCU21-V1 Operation Manual Download Page 474](http://html1.mh-extra.com/html/omron/sysmac-cj1w-scu21-v1/sysmac-cj1w-scu21-v1_operation-manual_743586474.webp)
445
Mitsubishi Computer Link Master (A-compatible 1C Frame, Model 1)
Appendix E
• Sending Device Read/Write Commands Common to AnA/AnU CPU
Sequence
No.
Communications
sequence name
Computer Link
command
Device type
Function
810 (032A) Device memory
batch read as word
data (all device
types except T/C)
QR (Device
memory batch
read as word
data)
Device other than
Timer/Counter
Reads the word data for the number of device
points starting from the specified device address
for the specified device type (except T, C) in the
Mitsubishi Computer Link Module with the speci-
fied station number (and the PLC number that
follows), converts the data into hexadecimal, and
stores it starting from the specified word + 2 in
the CS/CJ-series CPU Unit.
811 (032B) Device memory
batch read as word
data (T/C device
type)
Timer/Counter
(T, C)
Reads the word (PV) data for the number of
device points starting from the specified device
address for the specified device type (T, C) in the
Mitsubishi Computer Link Module with the speci-
fied station number (and the PLC number that
follows), converts the data into hexadecimal, and
stores it starting from the specified word + 2 in
the CS/CJ-series CPU Unit.
812 (032C) Device memory fill
as word data (all
device types except
T/C)
QW (Device
memory fill as
word data)
Device other than
Timer/Counter
Writes the word data starting from the specified
word + 7 in the CS/CJ-series CPU Unit to the
number of device points starting from the speci-
fied device address for the specified device type
(except T, C) in the Mitsubishi Computer Link
Module with the specified station number (and
the PLC number that follows).
813 (032D) Device memory fill
as word data (T/C
device type)
Timer/Counter
(T, C)
Writes the word (PV) data starting from the
specified word + 7 in the CS/CJ-series CPU Unit
to the number of device points starting from the
specified device address for the specified device
type (T, C) in the Mitsubishi Computer Link Mod-
ule with the specified station number (and the
PLC number that follows).
814 (032E) Device memory
batch read as bit
data (all device
types except T/C)
JR (Device mem-
ory batch read as
bit data)
Device other than
Timer/Counter
Reads the bit data for the number of device
points starting from the specified device address
for the specified device type (except T, C) in the
Mitsubishi Computer Link Module with the speci-
fied station number (and the PLC number that
follows), converts the data into hexadecimal, and
stores it starting from the specified word + 2 in
the CS/CJ-series CPU Unit.
815 (032F) Device memory
batch read as bit
data (T/C device
type)
Timer/Counter
(T, C)
Reads the bit (PV) data for the number of device
points starting from the specified device address
for the specified device type (T, C) in the Mitsub-
ishi Computer Link Module with the specified
station number (and the PLC number that fol-
lows), converts the data into hexadecimal, and
stores it starting from the specified word + 2 in
the CS/CJ-series CPU Unit.
816 (0330) Device memory fill
as bit data (all
device types except
T/C)
JW (Device
memory fill as bit
data)
Device other than
Timer/Counter
Writes the bit data starting from the specified
word + 7 in the CS/CJ-series CPU Unit to the
number of device points starting from the speci-
fied device address for the specified device type
(except T, C) in the Mitsubishi Computer Link
Module with the specified station number (and
the PLC number that follows).
817 (0331) Device memory fill
as bit data (T/C
device type)
Timer/Counter
(T, C)
Writes the bit (PV) data starting from the speci-
fied word + 7 in the CS/CJ-series CPU Unit to
the number of device points starting from the
specified device address for the specified device
type (T, C) in the Mitsubishi Computer Link Mod-
ule with the specified station number (and the
PLC number that follows).
Summary of Contents for SYSMAC CJ1W-SCU21-V1
Page 3: ...iv...
Page 5: ...vi...
Page 9: ...x...
Page 15: ...xvi...
Page 89: ...60 Basic Operating Procedure Section 1 9...
Page 151: ...122 RS 232C and RS 422A 485 Wiring Section 3 4...
Page 173: ...144 Host Link Function for Replacing Existing PLCs Section 4 6...
Page 223: ...194 Enhanced Protocol Macro Functions Section 5 6...
Page 277: ...248 Communications Frames Section 6 8...
Page 291: ...262 Basic Operating Procedure in No protocol Mode Section 7 4...
Page 301: ...272 Auxiliary Area and CIO Area Allocations Section 8 3...
Page 391: ...362 Introduction Appendix A...
Page 421: ...392 CompoWay F Master Protocol Appendix B...
Page 513: ...484 E5 K Digital Controller Read Protocol Appendix F...
Page 571: ...542 E5ZE Temperature Controller Write Protocol Appendix I...
Page 587: ...558 E5 J Temperature Controller Protocol Appendix J...
Page 627: ...598 ES100 Digital Controller Protocol Appendix K...
Page 661: ...632 V500 V520 Bar Code Reader Protocol Appendix M...
Page 697: ...668 3Z4L Laser Micrometer Protocol Appendix N...
Page 717: ...688 Visual Inspection System Protocol Appendix O...
Page 755: ...726 V600 V620 ID Controller Protocol Appendix P...
Page 763: ...734 Hayes Modem AT Command Protocol Appendix Q...
Page 767: ...738 Changing Communications Port Settings Using STUP 237 Appendix R...
Page 781: ...752 Revision History...