672
Visual Inspection System Protocol
Appendix O
Measurement Execution (F200) (Sequence No. 450 (Hex 01C2))
This sequence carries out one measurement and stores the measurement results in the specified words.
Send Data Word Allocation (3rd Operand of PMCR(260))
None.
Receive Data Word Allocation (4th Operand of PMCR(260))
Note
1.
Only one output No. can be stored.
2.
The ranges of measurement values are as follows:
For calibration OFF setting: –2147483.648 to 2147483.647
For calibration ON setting:
–9999999.999 to 9999999.999
3.
If a measurement value exceeds the range of measurement values when calibration is turned off, un-
defined data is stored in the specified words.
Continuous Measurement Execution (Scan) (F200)
(Sequence No. 451 (Hex 01C3))
This sequence carries out continuously the setting of the F200 and stores measurement results in the specified
words. The scan notification method is used for the receive data.
Send Data Word Allocation (3rd Operand of PMCR(260))
None.
Receive Data Word Allocation (4th Operand of PMCR(260))
Offset
Content (data format)
Data
+0
Number of receive data words
(4 digits Hex)
0006
+1
Output No. (2 digits BCD)
00 to 07
+2
Evaluation result (1 digit BCD)
0: OK
1: NG
+3 to +5 Measurement value (decimal portion)
(3 digits BCD)
Measurement value (integer portion)
(7 digits BCD)
Measurement value (sign)
(1 digit)
Integer portion
Receive data
storage words
Number of receive data words
+0
+1
+2
+3
+4
+5
(Undefined)
Output No.
(Undefined)
Measurement value
Evaluation
result
Decimal portion
0
Sign
Example
–123.456
+3
+4
+5
3456
0012
Example
+123.456
+3
+4
+5
3456
0012
F000
0000
F is stored for negative values.
Integer portion
Receive data
storage words
Number of receive data words
+0
+1
+2
+3
+4
+5
(Undefined)
Output No.
(Undefined)
Measurement value
Evaluation
result
Decimal portion
0
Sign
Summary of Contents for SYSMAC CJ1W-SCU21-V1
Page 3: ...iv...
Page 5: ...vi...
Page 9: ...x...
Page 15: ...xvi...
Page 89: ...60 Basic Operating Procedure Section 1 9...
Page 151: ...122 RS 232C and RS 422A 485 Wiring Section 3 4...
Page 173: ...144 Host Link Function for Replacing Existing PLCs Section 4 6...
Page 223: ...194 Enhanced Protocol Macro Functions Section 5 6...
Page 277: ...248 Communications Frames Section 6 8...
Page 291: ...262 Basic Operating Procedure in No protocol Mode Section 7 4...
Page 301: ...272 Auxiliary Area and CIO Area Allocations Section 8 3...
Page 391: ...362 Introduction Appendix A...
Page 421: ...392 CompoWay F Master Protocol Appendix B...
Page 513: ...484 E5 K Digital Controller Read Protocol Appendix F...
Page 571: ...542 E5ZE Temperature Controller Write Protocol Appendix I...
Page 587: ...558 E5 J Temperature Controller Protocol Appendix J...
Page 627: ...598 ES100 Digital Controller Protocol Appendix K...
Page 661: ...632 V500 V520 Bar Code Reader Protocol Appendix M...
Page 697: ...668 3Z4L Laser Micrometer Protocol Appendix N...
Page 717: ...688 Visual Inspection System Protocol Appendix O...
Page 755: ...726 V600 V620 ID Controller Protocol Appendix P...
Page 763: ...734 Hayes Modem AT Command Protocol Appendix Q...
Page 767: ...738 Changing Communications Port Settings Using STUP 237 Appendix R...
Page 781: ...752 Revision History...