![Omron SYSMAC CJ1W-SCU21-V1 Operation Manual Download Page 695](http://html1.mh-extra.com/html/omron/sysmac-cj1w-scu21-v1/sysmac-cj1w-scu21-v1_operation-manual_743586695.webp)
666
3Z4L Laser Micrometer Protocol
Appendix N
Receive Data Word Allocation (4th Operand of PMCR(260))
None.
General-purpose Command 2 (4000-series) (Sequence No. 445
(Hex 01BD))
This general-purpose command is used to send data with a specified data length, and receive back receive
data other than OK. The terminator (CR) is automatically attached to the send data.
Send Data Word Allocation (3rd Operand of PMCR(260))
Receive Data Word Allocation (4th Operand of PMCR(260))
Offset
Contents (data format)
Data
+0
Number of send data words
(4 digits Hex)
0003 to 00FA (3 to 250 decimal)
+1
Send data byte length (4 digits Hex)
0001 to 01F0 (1 to 496 decimal)
The number of bytes of send data excluding
the terminator (CR)
+2 to
+249
Send data (ASCII)
Send data up to 496 bytes maximum
Specify in ASCII.
Offset
Contents (data format)
Data
+0
Number of send data words
(4 digits Hex)
0003 to 00FA (3 to 250 decimal)
+1
Send data byte length
(4 digits Hex)
0001 to 01F0 (1 to 496 decimal)
The number of bytes of send data excluding
the terminator (CR)
+2 to
+249
Send data (ASCII)
Send data up to 496 bytes maximum
Specify in ASCII.
Offset
Contents (data format)
Data
+0
Number of receive data words
(4 digits BCD)
0001 to 00FA (1 to 250 decimal)
+1 to
+249
Receive data (ASCII)
When the receive data exceed 498 bytes,
only 498 bytes are stored.
First word of
send data
Number of send data words
+0
+1
+2
+3
+128
+249
Send data
Send data byte length
Send data
Send data
•
•
Send data
CR
Receive data
storage words
Number of receive data words
+0
+1
+2
+126
+249
Receive data
Receive data
Receive data
Receive data
•
•
Summary of Contents for SYSMAC CJ1W-SCU21-V1
Page 3: ...iv...
Page 5: ...vi...
Page 9: ...x...
Page 15: ...xvi...
Page 89: ...60 Basic Operating Procedure Section 1 9...
Page 151: ...122 RS 232C and RS 422A 485 Wiring Section 3 4...
Page 173: ...144 Host Link Function for Replacing Existing PLCs Section 4 6...
Page 223: ...194 Enhanced Protocol Macro Functions Section 5 6...
Page 277: ...248 Communications Frames Section 6 8...
Page 291: ...262 Basic Operating Procedure in No protocol Mode Section 7 4...
Page 301: ...272 Auxiliary Area and CIO Area Allocations Section 8 3...
Page 391: ...362 Introduction Appendix A...
Page 421: ...392 CompoWay F Master Protocol Appendix B...
Page 513: ...484 E5 K Digital Controller Read Protocol Appendix F...
Page 571: ...542 E5ZE Temperature Controller Write Protocol Appendix I...
Page 587: ...558 E5 J Temperature Controller Protocol Appendix J...
Page 627: ...598 ES100 Digital Controller Protocol Appendix K...
Page 661: ...632 V500 V520 Bar Code Reader Protocol Appendix M...
Page 697: ...668 3Z4L Laser Micrometer Protocol Appendix N...
Page 717: ...688 Visual Inspection System Protocol Appendix O...
Page 755: ...726 V600 V620 ID Controller Protocol Appendix P...
Page 763: ...734 Hayes Modem AT Command Protocol Appendix Q...
Page 767: ...738 Changing Communications Port Settings Using STUP 237 Appendix R...
Page 781: ...752 Revision History...