DM AREA WRITE
(Sequence No. 758 (Hex 02F6))
This sequence sends command code 0102 hex to the specified Host Link Unit and writes data to consecutive
DM Area words.
Send Data Word Allocation (3rd Operand of PMCR(260))
Receive Data Word Allocation (4th Operand of PMCR(260))
Offset
Contents (data format)
Data
+0
Number of send data words
(4 digits hex)
0007 to 00F4 hex (7 to 244 decimal)
+1
Host Link unit
No.
(2 digits BCD)
Remote destina-
tion network
address (DNA)
(2 digits hex)
Host Link unit number: 00 to 31
Remote destination network address
(DNA): 00 to 7F hex
+2
Remote destina-
tion node
address (DA1)
(2 digits hex)
Remote destina-
tion unit address
(DA2)
(2 digits hex)
Remote destination node address
(DA1): 00 to FE hex
Remote destination unit address (DA2):
00 to FE hex
+3
First write address (4 digits hex)
0000 to 7FFF hex
Specify the first write address
(4 digits hex)
+4
Number of write elements
(4 digits hex)
0001 to 00EE hex
Specify the number of write elements
+5
Number of write data bytes
(4 digits hex)
0004 to 03B8 hex
Specify the number of FINS command
text bytes for the communications line
(i.e., twice the number of write data
bytes in S+6 onwards)
+6
Write data (4 digits hex)
Write data to send to the first write
word
+7
on
Write data to send to the first write
word + 1 and onwards
+0
+1
+2
+3
+4
+5
+6
First word of
send data
Number of write elements
Number of send data words
First write address
Host Link unit number
Remote destination node
address
Number of write data bytes
Write data
Remote destination
network address
Remote destination
unit address
Offset
Contents (data format)
Data
+0
Number of receive data words
(4 digits hex)
Always 0002 hex (2 decimal)
+1
End code (4 digits hex)
The end code is stored in hexadecimal.
+0
+1
Receive data
storage words
Number of receive data words
End code
Summary of Contents for SYSMAC CJ1W-SCU21-V1
Page 3: ...iv...
Page 5: ...vi...
Page 9: ...x...
Page 15: ...xvi...
Page 89: ...60 Basic Operating Procedure Section 1 9...
Page 151: ...122 RS 232C and RS 422A 485 Wiring Section 3 4...
Page 173: ...144 Host Link Function for Replacing Existing PLCs Section 4 6...
Page 223: ...194 Enhanced Protocol Macro Functions Section 5 6...
Page 277: ...248 Communications Frames Section 6 8...
Page 291: ...262 Basic Operating Procedure in No protocol Mode Section 7 4...
Page 301: ...272 Auxiliary Area and CIO Area Allocations Section 8 3...
Page 391: ...362 Introduction Appendix A...
Page 421: ...392 CompoWay F Master Protocol Appendix B...
Page 513: ...484 E5 K Digital Controller Read Protocol Appendix F...
Page 571: ...542 E5ZE Temperature Controller Write Protocol Appendix I...
Page 587: ...558 E5 J Temperature Controller Protocol Appendix J...
Page 627: ...598 ES100 Digital Controller Protocol Appendix K...
Page 661: ...632 V500 V520 Bar Code Reader Protocol Appendix M...
Page 697: ...668 3Z4L Laser Micrometer Protocol Appendix N...
Page 717: ...688 Visual Inspection System Protocol Appendix O...
Page 755: ...726 V600 V620 ID Controller Protocol Appendix P...
Page 763: ...734 Hayes Modem AT Command Protocol Appendix Q...
Page 767: ...738 Changing Communications Port Settings Using STUP 237 Appendix R...
Page 781: ...752 Revision History...