650
3Z4L Laser Micrometer Protocol
Appendix N
Single Run Measurement Start (3000-series) (Sequence No. 410
(Hex 019A))
When the sample measurement condition is from 1 to 999, this sequence performs a single run measurement
and requests the measurement results
Send Data Word Allocation (3rd Operand of PMCR(260))
None.
Receive Data Word Allocation (4th Operand of PMCR(260))
Zero Run Measurement Start (3000-series) (Sequence No. 411
(Hex 019B))
If the sample measurement condition is zero, a zero run measurement is started.
Send Data Word Allocation (3rd Operand of PMCR(260))
None.
Receive Data Word Allocation (4th Operand of PMCR(260))
None.
Note
The zero run measurement keeps measuring until sequence No. 414 (Measurement Termination) is
executed.
Offset
Contents (data format)
Data
+0
Number of receive data
words (4 digit Hex)
With no reference setting: 0006
With reference setting: 0009
+1
Program number
(1 digit BCD)
0 to 9
+2
Decision result
(ASCII 2 characters)
With no limit setting: 0000
With limit setting: 2B4E (“+N”), 4F4B (“OK”),
2D4E (“–N”)
+3
Measurement value (decimal
portion)
(4 digits BCD)
0000 to 9999
+4
Measurement value (integer
portion) (3 digits BCD)
000 to 999
+5
Measurement value (Sign)
(BIN)
If +: 0
If –: F
+6 to +8 Deviation value
Same as measurement value
*The deviation will be stored in this area only when ref-
erence setting is made.
Receive data stor
age words
Number of receive data words
+0
+1
+2
+3
+4
+5
+6
+7
+8
Decimal portion
(Undefined)
Integer portion
Sign
Decimal portion
(Undefined)
(Undefined)
Integer portion
Sign
(Undefined)
(Undefined)
Decision result
Program number
Measurement value
Deviation value
4 5 6 7
0 1 2 3
F 0 0 0
+3
+4
+5
Example
–123.4567
Summary of Contents for SYSMAC CJ1W-SCU21-V1
Page 3: ...iv...
Page 5: ...vi...
Page 9: ...x...
Page 15: ...xvi...
Page 89: ...60 Basic Operating Procedure Section 1 9...
Page 151: ...122 RS 232C and RS 422A 485 Wiring Section 3 4...
Page 173: ...144 Host Link Function for Replacing Existing PLCs Section 4 6...
Page 223: ...194 Enhanced Protocol Macro Functions Section 5 6...
Page 277: ...248 Communications Frames Section 6 8...
Page 291: ...262 Basic Operating Procedure in No protocol Mode Section 7 4...
Page 301: ...272 Auxiliary Area and CIO Area Allocations Section 8 3...
Page 391: ...362 Introduction Appendix A...
Page 421: ...392 CompoWay F Master Protocol Appendix B...
Page 513: ...484 E5 K Digital Controller Read Protocol Appendix F...
Page 571: ...542 E5ZE Temperature Controller Write Protocol Appendix I...
Page 587: ...558 E5 J Temperature Controller Protocol Appendix J...
Page 627: ...598 ES100 Digital Controller Protocol Appendix K...
Page 661: ...632 V500 V520 Bar Code Reader Protocol Appendix M...
Page 697: ...668 3Z4L Laser Micrometer Protocol Appendix N...
Page 717: ...688 Visual Inspection System Protocol Appendix O...
Page 755: ...726 V600 V620 ID Controller Protocol Appendix P...
Page 763: ...734 Hayes Modem AT Command Protocol Appendix Q...
Page 767: ...738 Changing Communications Port Settings Using STUP 237 Appendix R...
Page 781: ...752 Revision History...