![Omron SYSMAC CJ1W-SCU21-V1 Operation Manual Download Page 219](http://html1.mh-extra.com/html/omron/sysmac-cj1w-scu21-v1/sysmac-cj1w-scu21-v1_operation-manual_743586219.webp)
190
Enhanced Protocol Macro Functions
Section 5-6
If the restore operation fails, the RDY Indicator will continue to flash. The CPU
Unit’s ERR/ALM Indicator will flash and bit A42409 (the Protocol Data Error
Flag) will be turned ON.
Serial Communications Unit Operation
The Serial Communications Unit’s RDY Indicator will flash during the restore
operation. Both the RDY Indicator and RUN Indicator will be lit when the
restore operation is completed normally.
If the restore operation fails, the RDY Indicator will continue to flash and the
ERC Indicator will be lit.
■
Comparing the Protocol Data with the Memory Card’s Protocol Data File
Follow these steps to compare the Serial Communications Board/Unit’s proto-
col data with the Protocol Data File in the Memory Card:
1.
Make the following settings to pins 7 and 8 in the DIP Switch on the front
of the CPU Unit.
2.
Press and hold the Memory Card power supply switch for 3 seconds.
This procedure compares the protocol data in the Serial Communications
Board/Unit with the data in the Protocol Data File in the CPU Unit’s Memory
Card.
When the Memory Card power supply switch is pressed, the MCPWR Indica-
tor on the front of the CPU Unit will flash once and then remain lit while the
data is being compared. If the data matches, the Indicator will go OFF after
the data has been compared.
5-6
Enhanced Protocol Macro Functions
Serial Communications Boards/Units with Unit Ver. 1.2 or later support the fol-
lowing enhanced protocol macro functions.
• Data exchange timing in link word specification
• Selection to clear or hold the contents of the reception buffer during full-
duplex communications
• High-speed baud rate in protocol macro mode
Pin
Setting
7
OFF
8
OFF
Serial Communications
Board/Unit
Protocol data
• Compare
Memory Card power supply switch
CPU Unit
All data
Memory Card
Summary of Contents for SYSMAC CJ1W-SCU21-V1
Page 3: ...iv...
Page 5: ...vi...
Page 9: ...x...
Page 15: ...xvi...
Page 89: ...60 Basic Operating Procedure Section 1 9...
Page 151: ...122 RS 232C and RS 422A 485 Wiring Section 3 4...
Page 173: ...144 Host Link Function for Replacing Existing PLCs Section 4 6...
Page 223: ...194 Enhanced Protocol Macro Functions Section 5 6...
Page 277: ...248 Communications Frames Section 6 8...
Page 291: ...262 Basic Operating Procedure in No protocol Mode Section 7 4...
Page 301: ...272 Auxiliary Area and CIO Area Allocations Section 8 3...
Page 391: ...362 Introduction Appendix A...
Page 421: ...392 CompoWay F Master Protocol Appendix B...
Page 513: ...484 E5 K Digital Controller Read Protocol Appendix F...
Page 571: ...542 E5ZE Temperature Controller Write Protocol Appendix I...
Page 587: ...558 E5 J Temperature Controller Protocol Appendix J...
Page 627: ...598 ES100 Digital Controller Protocol Appendix K...
Page 661: ...632 V500 V520 Bar Code Reader Protocol Appendix M...
Page 697: ...668 3Z4L Laser Micrometer Protocol Appendix N...
Page 717: ...688 Visual Inspection System Protocol Appendix O...
Page 755: ...726 V600 V620 ID Controller Protocol Appendix P...
Page 763: ...734 Hayes Modem AT Command Protocol Appendix Q...
Page 767: ...738 Changing Communications Port Settings Using STUP 237 Appendix R...
Page 781: ...752 Revision History...