K Digital Controller Read Protocol
Appendix F
Receive Data Word Allocation (4th Operand of PMCR(260))
Read Level 1 Parameters 1 (Sequence No. 019 (Hex 0013))
Reads parameters in level 1 (alarm value 1, alarm value 2, alarm value 3, proportional band, integral time, and
derivative time) from multiple units and stores the results in the specified words.
Send Data Word Allocation (3rd Operand of PMCR(260))
Offset
Contents (data format)
Data
+0
Number of receive data words
(4 digits Hex)
Number of units
×
5 + 1
+1
1st unit
Process value (4 digits BCD)
Scaling lower limit to upper limit
+2
1st unit
Set point during SP ramp
(4 digits BCD)
Set point lower limit to upper limit
+3
1st unit
MV (heating) (4 digits BCD)
F050 to 1050
F indicates a negative value.
0000 to 1050 for heating/cooling con-
trol
+4
1st unit
MV (cooling) (4 digits BCD)
0000 to 1050
+5
1st unit
Set point (4 digits BCD)
Set point lower limit to upper limit
•
•
•
+40
(max.)
8th unit
Set point (4 digits BCD)
Set point lower limit to upper limit
Offset
Contents (data format)
Data
+0
Number of send data words
(4 digits Hex)
Number of units + 2
+1
Number of units (4 digits Hex)
0001 to 0008
+2 to 9
Unit No. (2 digits BCD)
00 to 31
Process value
Receive
data storage
words
Number of receive data words
+0
+1
+2
+3
+4
+5
+36
+37
+38
+39
+40
Process value
Set point during SP ramp
MV (heating)
MV (cooling)
~
~
Set point during SP ramp
MV (heating)
MV (cooling)
Set point
1st unit
8th unit (max.)
Set point
(Undefined)
Unit No.
First word of
send data
Number of send data words
+0
+1
+2
+3
+9
(Undefined)
Unit No.
Number of units
(Undefined)
Unit No.
~
~
(max.)
Summary of Contents for SYSMAC CJ1W-SCU21-V1
Page 3: ...iv...
Page 5: ...vi...
Page 9: ...x...
Page 15: ...xvi...
Page 89: ...60 Basic Operating Procedure Section 1 9...
Page 151: ...122 RS 232C and RS 422A 485 Wiring Section 3 4...
Page 173: ...144 Host Link Function for Replacing Existing PLCs Section 4 6...
Page 223: ...194 Enhanced Protocol Macro Functions Section 5 6...
Page 277: ...248 Communications Frames Section 6 8...
Page 291: ...262 Basic Operating Procedure in No protocol Mode Section 7 4...
Page 301: ...272 Auxiliary Area and CIO Area Allocations Section 8 3...
Page 391: ...362 Introduction Appendix A...
Page 421: ...392 CompoWay F Master Protocol Appendix B...
Page 513: ...484 E5 K Digital Controller Read Protocol Appendix F...
Page 571: ...542 E5ZE Temperature Controller Write Protocol Appendix I...
Page 587: ...558 E5 J Temperature Controller Protocol Appendix J...
Page 627: ...598 ES100 Digital Controller Protocol Appendix K...
Page 661: ...632 V500 V520 Bar Code Reader Protocol Appendix M...
Page 697: ...668 3Z4L Laser Micrometer Protocol Appendix N...
Page 717: ...688 Visual Inspection System Protocol Appendix O...
Page 755: ...726 V600 V620 ID Controller Protocol Appendix P...
Page 763: ...734 Hayes Modem AT Command Protocol Appendix Q...
Page 767: ...738 Changing Communications Port Settings Using STUP 237 Appendix R...
Page 781: ...752 Revision History...