675
Visual Inspection System Protocol
Appendix O
Evaluation Condition Change (F200)
(Sequence No. 456 (Hex 01C8))
This sequence changes the upper and lower limit values of evaluation condition of the designated output No.
Send Data Word Allocation (3rd Operand of PMCR(260))
Receive Data Word Allocation (4th Operand of PMCR(260))
None.
Note
1.
Only one output No. can be designated.
2.
Enter values so that upper limit
≥
lower limit.
3.
Enter upper limit and lower limit values within the range –2147483.648 to 2147483.648.
Arbitrary Measurement Value Acquisition (F200)
(Sequence No. 457 (Hex 01C9))
This sequence stores measurement values of arbitrary measurement items regardless of output format in the
specified words.
Send Data Word Allocation (3rd Operand of PMCR(260))
Offset
Content (data format)
Data
+0
Number of send data words
(4 digits Hex)
000A (0010 decimal)
+1
Output No. (2 digits BCD)
00 to 07
+2 to +5 Upper limit value (decimal portion)
(3 digits BCD)
Upper limit value (integer portion)
(7 digits BCD)
Upper limit value (sign) (ASCII 2 digits)
+6 to +9 Lower limit value (decimal portion)
(3 digits BCD)
Same as upper limit.
Lower limit value (integer portion)
(7 digits BCD)
Lower limit value (sign) (ASCII 2 digits)
Integer portion
First word of send
data
Number of send data words
+0
+1
+2
+3
+4
+5
+6
+7
+8
+9
(Undefined)
Output No.
(Undefined)
Upper limit value
Decimal portion
(Undefined)
Sign
(Undefined)
Integer portion
(Undefined)
Lower limit value
Decimal portion
(Undefined)
Sign
(Undefined)
Example
–123.456
+2
+3
+4
+5
0567
1234
Example
+123.456
+2
+3
+4
+5
0678
2345
0000
0001
2D00
3000
First word of
send data
Number of send data words
+0
+1
+2
(Undefined)
Data 1
(Undefined)
Data 2
Summary of Contents for SYSMAC CJ1W-SCU21-V1
Page 3: ...iv...
Page 5: ...vi...
Page 9: ...x...
Page 15: ...xvi...
Page 89: ...60 Basic Operating Procedure Section 1 9...
Page 151: ...122 RS 232C and RS 422A 485 Wiring Section 3 4...
Page 173: ...144 Host Link Function for Replacing Existing PLCs Section 4 6...
Page 223: ...194 Enhanced Protocol Macro Functions Section 5 6...
Page 277: ...248 Communications Frames Section 6 8...
Page 291: ...262 Basic Operating Procedure in No protocol Mode Section 7 4...
Page 301: ...272 Auxiliary Area and CIO Area Allocations Section 8 3...
Page 391: ...362 Introduction Appendix A...
Page 421: ...392 CompoWay F Master Protocol Appendix B...
Page 513: ...484 E5 K Digital Controller Read Protocol Appendix F...
Page 571: ...542 E5ZE Temperature Controller Write Protocol Appendix I...
Page 587: ...558 E5 J Temperature Controller Protocol Appendix J...
Page 627: ...598 ES100 Digital Controller Protocol Appendix K...
Page 661: ...632 V500 V520 Bar Code Reader Protocol Appendix M...
Page 697: ...668 3Z4L Laser Micrometer Protocol Appendix N...
Page 717: ...688 Visual Inspection System Protocol Appendix O...
Page 755: ...726 V600 V620 ID Controller Protocol Appendix P...
Page 763: ...734 Hayes Modem AT Command Protocol Appendix Q...
Page 767: ...738 Changing Communications Port Settings Using STUP 237 Appendix R...
Page 781: ...752 Revision History...