7 - 49
7 Parameter Details
OMNUC G5-series (Pulse-train Input Type) AC Servomotors and Servo Drives User’s Manual
7-6 Exten
d
ed
P
arameter
s
7
Explanation of Set Values
• Select the signal read cycle for control signals.
Explanation of Set Values
• Select the time during which the RESET signal must last to be recognized as an Alarm Reset Input signal.
Explanation of Set Values
• The minimum duration of the RESET input signal when the parameter is set to 1 or 2 is as follows.
• The minimum duration of the RESET input signal when the parameter is set to 3 or 4 is as follows.
Pn515
Control Input Signal Read Setting
Setting
range
0 to 3
Unit
–
Default
setting
0
Cycle the
power supply
Required
Set value
Description
0
0.166 ms
1
0.333 ms
2
1 ms
3
1.666 ms
Pn516
Alarm Reset Condition Setting
Setting
range
0 to 1
Unit
–
Default
setting
0
Cycle the
power supply
Required
Set value
Description
0
120 ms
1
Follow the setting of Control Input Signal Read Setting (Pn515).
Pn517
Error Counter Reset Condition Selection
Setting
range
0 to 4
Unit
–
Default
setting
3
Cycle the
power supply
–
Set value
Description
0
Disabled
1
Clear the error counter at level when the signal is shorted for 500 µs or longer.
2
Clear the error counter at level when the signal is shorted for 1 ms or longer.
3
Clear the error counter at edge when the signal changes from open to shorted for 100 µs or longer.
4
Clear the error counter at edge when the signal changes from open to shorted for 1 ms or longer.
All
All
Position
Resetting error continues
Set value 1: 500 μs or more
Set value 2: 1 ms or more
Error Counter
Reset Input signal
Resetting error occurs only once
Set value 3: 100 μs or more
Set value 4: 1 ms or more
Error Counter
Reset Input signal