7 Parameter Details
OMNUC G5-series (Pulse-train Input Type) AC Servomotors and Servo Drives User’s Manual
7-5 Interface Mo
nitor Setting
P
a
rameter
s
7
• Set the output gain of the analog monitor 2.
• Select the analog monitor output voltage direction.
• An example when the monitor type is Motor speed and the conversion gain is 500 (1 V = 500 r/min)
• Do not set.
• Do not set.
Pn419
Analog Monitor 2 Scale Setting
Setting
range
0 to 214,748,364
Unit
Pn418 monitor unit/V
Default
setting
0
Cycle the
power supply
–
Pn421
Analog Monitor Output Setting
Setting
range
0 to 2
Unit
–
Default
setting
0
Cycle the
power supply
–
Set value
Output range
Data output
0
–10 to 10 V
1
0 to 10 V
2
0 to 10 V
Pn422
Reserved
Setting
range
0
Unit
–
Default
setting
0
Cycle the
power supply
–
Pn423
Reserved
Setting
range
0
Unit
–
Default
setting
0
Cycle the
power supply
–
All
All
10 V
–10 V
0 V
–5,000
5,000 [r/min]
Motor
speed
Output voltage [V]
10 V
–10 V
0 V
–5,000
5,000 [r/min]
Motor
speed
Output voltage [V]
10 V
5 V
–10 V
0 V
0
–2,500
5,000 [r/min]
Motor
speed
Output voltage [V]