3 - 33
3 Specifications
OMNUC G5-series (Pulse-train Input Type) AC Servomotors and Servo Drives User’s Manual
3-1 Ser
v
o Drive Sp
ecification
s
3
3-1-10
A
n
alog Mo
nitor Connec
tor S
p
ecifications (CN
5
)
Monitor Output (CN5)
Connectors for CN5 (6 Pins)
3-1-10 Analog Monitor Connector Specifications (CN5)
Monitor Output Signal Table
Pin
No.
Symbol
Name
Function and interface
1
AM1
Analog monitor
output 1
Outputs the analog signal for the monitor.
Default setting: Motor rotation speed 1 V/(500 r/min)
The item and the unit can be changed using Pn416 and Pn417.
The output method can be changed using Pn421.
2
AM2
Analog monitor
output 2
Outputs the analog signal for the monitor.
Default setting: Torque command 1 V/(33%)
The item and the unit can be changed using Pn418 and Pn419.
The output method can be changed using Pn421.
3
GND
Analog monitor
ground
Ground for analog monitors 1, 2
4
–
Not used
Do not connect.
5
–
Not used
Do not connect.
6
–
Not used
Do not connect.
Name
Model
Manufacturer
Connector housing
51004-0600
Molex Japan
Connector terminal
50011-8000
Molex Japan
Monitor Output Circuit
Servo Drive
Monitor equipment
3 GND
1/2 AM1/AM2
1 k
+
–
Summary of Contents for G5 R88D-KE Series
Page 3: ...2 Page 2 53 For 1 000 r min Servomotors 900 W to 3 kW Current Contents Corrected Contents...
Page 504: ......