7 Parameter Details
7 - 20
OMNUC G5-series (Pulse-train Input Type) AC Servomotors and Servo Drives User’s Manual
7-3
Vibration Suppression Parameters
Explanation of Set Values
• Set the operation of the adaptive filter.
• Set the frequency of the first resonance suppression notch filter.
• When set to 5,000, the notch filter function is disabled.
• Set the width of the first resonance suppression notch filter in 20 levels.
• Increasing the setting value widens the notch width. Normally, use the default set value.
• Set the notch depth of the first resonance suppression notch filter.
• Increasing the setting value shortens the notch depth and the phase lag.
• Set the notch frequency of the second resonance suppression notch filter.
• When set to 5,000, the notch filter function is disabled.
Pn200
Adaptive Filter Selection
Setting
range
0 to 4
Unit
–
Default
setting
0
Cycle the
power supply
–
Set value
Description
0
Disabled. The parameters related to notch filters 3 and 4 hold the current values.
1
One filter enabled. The parameters related to notch filter 3 are updated according to the adaptive
result.
2
Two filters enabled. The parameters related to notch filters 3 and 4 are updated according to the
adaptive result.
3
Resonance frequency measured. The measurement result can be checked in CX-Drive. The
parameters related to notch filters 3 and 4 hold the current values.
4
Adaptive result cleared. The parameters related to notch filters 3 and 4 are disabled and the
adaptive result is cleared.
Pn201
Notch 1 Frequency Setting
Setting
range
50 to 5,000
Unit
Hz
Default
setting
5,000
Cycle the
power supply
–
Pn202
Notch 1 Width Setting
Setting
range
0 to 20
Unit
–
Default
setting
2
Cycle the
power supply
–
Pn203
Notch 1 Depth Setting
Setting
range
0 to 99
Unit
–
Default
setting
0
Cycle the
power supply
–
Pn204
Notch 2 Frequency Setting
Setting
range
50 to 5,000
Unit
Hz
Default
setting
5,000
Cycle the
power supply
–
Position Speed
All
All
All
All