8 - 23
8 Operation
OMNUC G5-series (Pulse-train Input Type) AC Servomotors and Servo Drives User’s Manual
8-4 Mod
e Setting
8
8-4
-5 A
uxilia
ry Function Mode
Do not set.
Trial operation can be performed with no-load, i.e., without connecting the control I/O connector (CN1) to
the Servomotor.
1
Preparations for jog operation
2
Perform jog operation.
3
Return to the auxiliary function mode display.
Reserved
Jog Operation
Key
operation
Display example
Description
From the auxiliary function mode alarm clear display, press the
key to
switch to the jog operation mode display.
Press
key to switch to the jog operation mode display.
Press and hold
key for 5 seconds or more (until
appears).
The number of dashes on the display increases.
The jog operation is ready.
If
is displayed, the servo is not ready.
Press and hold
key for 5 seconds or more (until
appears).
The decimal point moves leftward.
The servo is turned ON.
Key
operation
Display example
Description
Pressing the
key enables the Servomotor to rotate in the forward
direction; pressing the
key enables the Servomotor to rotate in the
reverse direction. The Servomotor stops rotating when you release the key.
At this time, the rotation speed set in Jog Speed (Pn604) will be used.
If
is displayed, the servo is not ready.
Key
operation
Display example
Description
Press
key to return to the auxiliary function mode display.
The servo is unlocked and in a servo-free state.
fkn
fkn
fkn
fkn