6 - 35
6 Applied Functions
OMNUC G5-series (Pulse-train Input Type) AC Servomotors and Servo Drives User’s Manual
6-9 Seq
u
en
ce I/O Signa
ls
6
6-9-2 Inpu
t Signals
Function Number Table
The set values to be used for allocations are as follows:
*1
The Operation Command (RUN) must be allocated. Servo cannot be turned ON if it is not allocated.
*2
Allocate this signal to Input Signal Selection 7 (Pn406). If it is allocated to any other signal, an alarm will occur.
*3
Allocate this signal to Input Signal Selection 10 (Pn409). If it is allocated to any other signal, an alarm will
occur.
Precautions for Correct Use
Precautions for Correct Use
• Do not use any values other than the settings listed.
• If you allocate the same function to more than one input signal, Interface Input Duplicate
Allocation Error 1 (Alarm No. 33.0) or Interface Input Duplicate Allocation Error 2 (Alarm No.
33.1) will occur.
• Error Counter Reset Input (ECRST) can be allocated only to Input Signal Selection 7 (Pn406).
If it is allocated to other signals, Counter Reset Allocation Error (Alarm No. 33.6) will occur.
• Pulse Prohibition Input (IPG) can be allocated only to Input Signal Selection 10 (Pn409). If it is
allocated to signals, Command Pulse Prohibition Input Allocation Error (Alarm No. 33.7) will
occur.
• To use Control Mode Switching Input (TVSEL), it must be set for all control modes. Otherwise,
Interface Input Function Number Error 1 (Alarm No. 33.2) or Interface Input Function Number
Error 2 (Alarm No. 33.3) will occur.
• If Zero Speed Designation Selection (Pn315) is set to 2 or 3, the Zero Speed Designation
Input (VZERO) for the position control must be allocated to the same pin as that to which the
Zero Speed Designation Input (VZERO) for the speed control is allocated. The logic must also
be allocated in the same method.
Signal
Symbol
Set value
NO
NC
Disabled
–
00 hex
Setting not available
Forward Drive Prohibition Input
POT
01 hex
81 hex
Reverse Drive Prohibition Input
NOT
02 hex
82 hex
Operation Command
*1
RUN
03 hex
83 hex
Alarm Reset Input
RESET
04 hex
Setting not available
Control Mode Switching Input
TVSEL
05 hex
85 hex
Gain Switching
GSEL
06 hex
86 hex
Error Counter Reset Input
*2
ECRST
07 hex
Setting not available
Pulse Prohibition Input
*3
IPG
08 hex
88 hex
Torque Limit Switching
TLSEL
09 hex
89 hex
Damping Filter Switching 1
DFSEL1
0A hex
8A hex
Damping Filter Switching 2
DFSEL2
0B hex
8B hex
Electronic Gear Switching Input 1
GESEL1
0C hex
8C hex
Electronic Gear Switching Input 2
GESEL2
0D hex
8D hex
No. 1 Internally Set Speed
VSEL1
0E hex
8E hex
No. 2 Internally Set Speed
VSEL2
0F hex
8F hex
No. 3 Internally Set Speed
VSEL3
10 hex
90 hex
Zero Speed Designation Input
VZERO
11 hex
91 hex
Speed Command Sign Input
VSIGN
12 hex
92 hex
Emergency Stop Input
STOP
14 hex
94 hex
Inertia Ratio Switching Input
J-SEL
15 hex
95 hex