7 - 3
7 Parameter Details
OMNUC G5-series (Pulse-train Input Type) AC Servomotors and Servo Drives User’s Manual
7-
1
B
a
si
c
P
a
ra
m
e
te
rs
7
Explanation of Set Values
• Set the control mode to be used.
• Selecting the combined mode (set value: 3) enables the selection of Mode 1 or Mode 2 based on the
Control Mode Switching Input (TVSEL).
• If Control Mode Switching Input is open: Mode 1 is selected.
• If Control Mode Switching Input is shorted: Mode 2 is selected.
• Do not input commands during 10 ms before and after mode switching operation.
Explanation of Set Values
• Set the realtime autotuning operation mode.
Pn001
Control Mode Selection
Setting
range
0 to 6
Unit
–
Default
setting
0
Cycle the
power supply
Required
Set value
Description
0
Position control (Pulse-train command)
1
Speed control (Internally set speed control)
2
Reserved (Do not set.)
3
Mode 1: Position control, Mode 2: Speed control (Internally set speed control)
4
Reserved (Do not set.)
5
Reserved (Do not set.)
6
Reserved (Do not set.)
Pn002
Realtime Autotuning Mode Selection
Setting
range
0 to 6
Unit
–
Default
setting
1
Cycle the
power supply
–
Set value
Description
0
Disabled
1
Focus on stability
2
Focus on positioning
3
Used when unbalanced load is present, i.e., with a vertical axis, etc.
4
Used when a vertical axis or other unbalanced load is present and when friction is large.
5
Used only for estimating load characteristics.
6
Used for customizing the realtime autotuning mode.
All
Mode 1
Mode 2
Closed
Open
Control Mode
Switching Input
10 ms or more
10 ms or more
Open
Mode 1
All