8 Operation
8 - 26
OMNUC G5-series (Pulse-train Input Type) AC Servomotors and Servo Drives User’s Manual
6
Save the changed setting to memory.
7
Return to the parameter write mode display.
8
Turn OFF and then ON the power supply again.
Precautions for Correct Use
Precautions for Correct Use
• Items which are limited vary depending on the mode setting.
• If the Front Panel Parameter Write Selection (Pn617) is set to 1, the parameter set value is
automatically written to EEPROM when changed.
• For details about the front panel lock function, refer to Front Key Protection Setting (Pn535) in
7-6 Extended Parameters on page 7-42.
Key
operation
Display example
Description
Press
key to switch to the parameter write mode display.
Press
key to switch to the parameter write mode display.
Press and hold
key for 5 seconds or more (until
appears).
The number of dashes on the display increases.
The parameter write process starts. (This display appears only
momentarily.)
This indicates a normal completion. Other than this, the follwing displays
may be shown
and
.
also indicates a normal completion, but it means that some of
the changed parameters are enabled only after the system is restarted.
Turn OFF and then ON the power supply again.
indicates a write alarm. Write the data again.
Key
operation
Display example
Description
Press
key to return to the parameter write mode display.