3 Specifications
3 - 42
OMNUC G5-series (Pulse-train Input Type) AC Servomotors and Servo Drives User’s Manual
Brake Specifications
*1
These are the values when the Servomotor is combined with a Servo Drive at normal temperature (20°C, 65%). The
momentary maximum torque indicates the standard value.
*2
Applicable load inertia
• The operable load inertia ratio (load inertia/rotor inertia) depends on the mechanical configuration and its rigidity. For a
machine with high rigidity, operation is possible even with high load inertia. Select an appropriate Servomotor and
confirm that operation is possible.
• The dynamic brake is rated for short-term operation. Use it only for emergency stopping. Configure the system to stop
for at least three minutes after the dynamic brake operates. Otherwise, the dynamic brake circuits may fail or the
dynamic brake resistor may burn.
*3
The allowable radial and thrust loads are the values determined for a limit of 20,000 hours at normal operating
temperatures.
The allowable radial loads are applied as shown in the following diagram.
*4
This is a non-excitation brake. (It is released when excitation voltage is applied.)
*5
The operation time is the value (reference value) measured with a surge suppressor (CR50500 by Okaya Electric
Industries Co., Ltd.).
*6
Direct current switching with a varistor (Z15D151 by Ishizuka Electronics Co.).
*7
Direct current switching with a varistor (TNR9G820K by Nippon Chemi-Con Corporation).
Model (R88M-)
200 VAC
Item
Unit
KE2K030H
KE3K030H
KE4K030H
KE5K030H
Brake inertia
kg·m
2
0.33 x 10
-4
0.33 x 10
-4
1.35 x 10
-4
1.35 x 10
-4
Excitation voltage
*4
V
24 VDC±10%
Power consumption (at 20°C)
W
19
19
22
22
Current consumption (at 20°C)
A
0.81±10%
0.81±10%
0.90±10%
0.90±10%
Static friction torque
N·m
7.8 min.
11.8 min.
16.1 min.
16.1 min.
Attraction time
*5
ms
50 max.
80 max.
110 max.
110 max.
Release time
*5
ms
15 max.
*6
15 max.
*6
50 max.
*7
50 max.
*7
Backlash
±1°
Allowable work per braking
J
392
392
1,470
1,470
Allowable total work
J
4.9 x 10
6
4.9 x 10
6
2.2 x 10
6
2.2 x 10
6
Allowable angular
acceleration
rad/s
2
10,000
Brake life
–
10 million times min.
Rating
–
Continuous
Insulation class
–
Class F
Radial load
Thrust load
Shaft center (T/2)