440
CompoBus/S I/O Link Units
Section 7-6
(2)
DIP Switch
Used to specify the node number for the CompoBus/S I/O Link Unit.
(Refer to the following table.)
(3)
LED Indicators
Used to show the CompoBus/S communications status.
(4)
Expansion I/O Connecting Cable
Connected to the expansion connector of a CP1H CPU Unit or a CMP1A
Expansion Unit or Expansion I/O Unit. The cable is provided with the
CompoBus/S I/O Link Unit and cannot be removed.
Note
Do not touch the cables during operation. Static electricity may
cause operating errors.
(5)
Expansion Connector
Used to connect CPM1A Expansion Units or Expansion I/O Units.
Pin labels
Contents
1
2
4
8
DR
HOLD
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
1 = ON, 0 = OFF
ON
OFF
ON
OFF
Long-distance communications mode (See note.)
High-speed communications mode
Retain inputs after a communications error.
Clear inputs after a communications error.
ON
1
2
4
8
DR
HOLD
SW1
8 4 2 1
0 0 0 0
0 0 0 1
0 0 1 0
0 0 1 1
0 1 0 0
0 1 0 1
0 1 1 0
0 1 1 1
1 0 0 0
1 0 0 1
1 0 1 0
1 0 1 1
1 1 0 0
1 1 0 1
1 1 1 0
1 1 1 1
NODE NUMBER
SW1
Node Number
Setting
Note: The long-distance communications
mode can be used only when one of
the following Master Units is
connected: C200HW-SRM21-V1,
CQM1-SRM21-V1, or SRM1-C0
@
-V2.
Indicator
Name
Color
Meaning
COMM
Communications
indicator
Yellow
ON:
Communications in progress.
OFF: Communications stopped or error
has occurred.
ERR
Error indicator
Red
ON:
A communications error has
occurred.
OFF: Indicates normal communications
or stand-by.
Summary of Contents for CP1H-CPU - 05-2006
Page 2: ...CP1H X40D CP1H XA40D CP1H Y20DT D CP1H CPU Unit Operation Manual Revised May 2006...
Page 3: ...iv...
Page 11: ...xii TABLE OF CONTENTS...
Page 15: ...xvi...
Page 19: ...xx...
Page 31: ...xxxii Conformance to EC Directives 6...
Page 71: ...40 Function Blocks Section 1 5...
Page 133: ...102 Computing the Cycle Time Section 2 7...
Page 169: ...138 CPM1A Expansion I O Unit Wiring Section 3 6...
Page 411: ...380 Clock Section 6 8...
Page 519: ...488 Replacing User serviceable Parts Section 10 2...
Page 527: ...496 Standard Models Appendix A...
Page 535: ...504 Dimensions Diagrams Appendix B...
Page 628: ...597 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Page 629: ...598 Connections to Serial Communications Option Boards Appendix F...
Page 659: ...628 PLC Setup Appendix G...
Page 665: ...634 Index work words 159 write protection 370...
Page 667: ...636 Revision History...