Interrupt Functions
Section 5-1
Setting the Input Functions in the PLC Setup
Normally, bits CIO 0.00 to CIO 0.01 and CIO 1.00 to CIO 1.03 are used as
normal inputs. When using these inputs for input interrupts, use the CX-Pro-
grammer to change the input’s setting in the PLC Setup.
Procedure
Input terminal
block
Input operation setting
Task number
Word
Bit
Normal inputs
Input interrupt
CIO 0
00
Normal input 0
Input interrupt 0
Interrupt task 140
01
Normal input 1
Input interrupt 1
Interrupt task 141
04, 05, 10
and 11
Normal inputs 2, 3, 4,
and 5
---
---
CIO 1
00
Normal input 6
Input interrupt 2
Interrupt task 142
01
Normal input 7
Input interrupt 3
Interrupt task 143
02
Normal input 8
Input interrupt 4
Interrupt task 144
03
Normal input 9
Input interrupt 5
Interrupt task 145
04 and 05 Normal inputs 10 and
11
---
---
Select the input interrupts.
• Determine the inputs to be used for input
interrupts and corresponding task numbers.
↓
Wire the inputs.
• Wire the inputs.
↓
Set the PLC Setup.
• Use the CX-Programmer to select the inter-
rupt inputs in the PLC Setup.
↓
Write the ladder program.
• Write the programs for the corresponding
interrupt task numbers.
• Use MSKS(690) to specify up-differentiation
or down-differentiation.
• Use MSKS(690) to enable input interrupts (in
direct mode).
Summary of Contents for CP1H-CPU - 05-2006
Page 2: ...CP1H X40D CP1H XA40D CP1H Y20DT D CP1H CPU Unit Operation Manual Revised May 2006...
Page 3: ...iv...
Page 11: ...xii TABLE OF CONTENTS...
Page 15: ...xvi...
Page 19: ...xx...
Page 31: ...xxxii Conformance to EC Directives 6...
Page 71: ...40 Function Blocks Section 1 5...
Page 133: ...102 Computing the Cycle Time Section 2 7...
Page 169: ...138 CPM1A Expansion I O Unit Wiring Section 3 6...
Page 411: ...380 Clock Section 6 8...
Page 519: ...488 Replacing User serviceable Parts Section 10 2...
Page 527: ...496 Standard Models Appendix A...
Page 535: ...504 Dimensions Diagrams Appendix B...
Page 628: ...597 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Page 629: ...598 Connections to Serial Communications Option Boards Appendix F...
Page 659: ...628 PLC Setup Appendix G...
Page 665: ...634 Index work words 159 write protection 370...
Page 667: ...636 Revision History...