278
Pulse Outputs
Section 5-3
S
First
set-
tings
table
word
S
Acceleration rate:
0001 to FFFF hex (1 to 65,535 Hz)
Specify the increase or decrease in the frequency per
pulse control period (4 ms).
S+1
Deceleration rate:
0001 to FFFF hex (1 to 65,535 Hz)
Specify the increase or decrease in the frequency per
pulse control period (4 ms).
S+2 and
S+3
S+2 and S+3 contain the target frequency setting, in
units of 1 Hz. (S+2 contains the rightmost 4 digits and
S+3 contains the leftmost 4 digits.)
X/XA CPU Units:
Unit version 1.1 and later:
• Pulse outputs 0 to 3:
00000001 to 000186A0 hex (0 Hz to 100 kHz)
Unit version 1.0 and earlier:
• Pulse outputs 0 and 1:
00000000 to 000186A0 hex (0 Hz to 100 kHz)
• Pulse outputs 2 and 3:
00000000 to 00007530 hex (0 Hz to 30 kHz)
Y CPU Units:
• Pulse outputs 0 and 1:
00000000 to 000F4240 hex (0 Hz to 1 MHz)
• Pulse outputs 2 and 3:
00000000 to 0000186A0 hex (0 Hz to 100 kHz)
S+4 and
S+5
S+4 and S+5 contain the number of pulses setting. (S+4
contains the rightmost 4 digits and S+5 contains the left-
most 4 digits.)
Relative pulse output:
00000000 to 7FFFFFFF hex (0 to 2,147,483,647)
Absolute pulse output:
80000000 to 7FFFFFFF hex (-2,147,483,648 to
2,147,483,647)
F
First starting fre-
quency word
F and F+1 contain the starting frequency setting, in units
of 1 Hz. (F contains the rightmost 4 digits and F+1 con-
tains the leftmost 4 digits.)
X/XA CPU Units:
Unit version 1.1 and later:
• Pulse outputs 0 to 3:
00000000 to 000186A0 hex (0 Hz to 100 kHz)
Unit version 1.0 and earlier:
• Pulse outputs 0 and 1:
00000000 to 000186A0 hex (0 Hz to 100 kHz)
• Pulse outputs 2 and 3:
00000000 to 00007530 hex (0 Hz to 30 kHz)
Y CPU Units:
• Pulse outputs 0 and 1:
00000000 to 000F4240 hex (0 Hz to 1 MHz)
• Pulse outputs 2 and 3:
00000000 to 000186A0 hex (0 Hz to 100 kHz)
Operand
Contents
Summary of Contents for CP1H-CPU - 05-2006
Page 2: ...CP1H X40D CP1H XA40D CP1H Y20DT D CP1H CPU Unit Operation Manual Revised May 2006...
Page 3: ...iv...
Page 11: ...xii TABLE OF CONTENTS...
Page 15: ...xvi...
Page 19: ...xx...
Page 31: ...xxxii Conformance to EC Directives 6...
Page 71: ...40 Function Blocks Section 1 5...
Page 133: ...102 Computing the Cycle Time Section 2 7...
Page 169: ...138 CPM1A Expansion I O Unit Wiring Section 3 6...
Page 411: ...380 Clock Section 6 8...
Page 519: ...488 Replacing User serviceable Parts Section 10 2...
Page 527: ...496 Standard Models Appendix A...
Page 535: ...504 Dimensions Diagrams Appendix B...
Page 628: ...597 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Page 629: ...598 Connections to Serial Communications Option Boards Appendix F...
Page 659: ...628 PLC Setup Appendix G...
Page 665: ...634 Index work words 159 write protection 370...
Page 667: ...636 Revision History...