164
Data Memory Area (D)
Section 4-14
4-13-3 Changing the BCD or Binary Mode for Counters and Timers
The refresh method for set values and present values for timers and counters
can be changed from BCD mode (0000 to 9999) to binary method (0000 to
FFFF) using the CX-Programmer
This setting is made in common for all tasks for all timers and counters.
1.
Right-click New PLC in the project tree and select Properties.
2.
Select the Execute Timer/Counter as Binary Option in the PLC Properties
Dialog Box. The timers and counters for all tasks will be executed in binary
mode.
4-14 Data Memory Area (D)
The DM Area contains 32,768 words with addresses ranging from D0 to
D32767. This data area is used for general data storage and manipulation
and is accessible only by word.
Data in the DM Area is retained when the PLC’s power is cycled or the PLC’s
operating mode is changed from PROGRAM mode to RUN/MONITOR mode
or vice-versa.
Although bits in the DM Area cannot be accessed directly, the status of these
bits can be accessed with the BIT TEST instructions, TST(350) and
TSTN(351).
Summary of Contents for CP1H-CPU - 05-2006
Page 2: ...CP1H X40D CP1H XA40D CP1H Y20DT D CP1H CPU Unit Operation Manual Revised May 2006...
Page 3: ...iv...
Page 11: ...xii TABLE OF CONTENTS...
Page 15: ...xvi...
Page 19: ...xx...
Page 31: ...xxxii Conformance to EC Directives 6...
Page 71: ...40 Function Blocks Section 1 5...
Page 133: ...102 Computing the Cycle Time Section 2 7...
Page 169: ...138 CPM1A Expansion I O Unit Wiring Section 3 6...
Page 411: ...380 Clock Section 6 8...
Page 519: ...488 Replacing User serviceable Parts Section 10 2...
Page 527: ...496 Standard Models Appendix A...
Page 535: ...504 Dimensions Diagrams Appendix B...
Page 628: ...597 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Page 629: ...598 Connections to Serial Communications Option Boards Appendix F...
Page 659: ...628 PLC Setup Appendix G...
Page 665: ...634 Index work words 159 write protection 370...
Page 667: ...636 Revision History...