![background image](http://html1.mh-extra.com/html/omron/cp1h-cpu-05-2006/html/omron/cp1h-cpu-05-2006/cp1h-cpu-05-2006_operation-manual_742082085.webp)
54
Specifications
Section 2-2
Setting Input Functions in
the PLC Setup
Functions for the normal input terminals in the built-in inputs can be individu-
ally allocated by making selections in the PLC Setup.
Note
Set using the MSKS instruction in direct mode or counter mode.
Input
terminal
block
Input operation
High-speed counter
operation
Origin search function
Word
Bit
Normal inputs
Interrupt inputs
(See note.)
Quick-
response
inputs
High-speed counters 0
to 3 set to be used.
Origin search function
for pulse outputs 0 to 3
set to be used.
CIO 0
00
Normal input 0
Interrupt input 0
Quick-response
input 0
---
Pulse 0: Origin input sig-
nal
01
Normal input 1
Interrupt input 1
Quick-response
input 1
High-speed counter 2
(phase-Z/reset)
Pulse 0: Origin proximity
input signal
02
Normal input 2
Interrupt input 2
Quick-response
input 2
High-speed counter 1
(phase-Z/reset)
Pulse output 1: Origin
input signal
03
Normal input 3
Interrupt input 3
Quick-response
input 3
High-speed counter 0
(phase-Z/reset)
Pulse output 1: Origin
proximity input signal
04
Normal input 4
---
---
High-speed counter 2
(phase-A, increment, or
count input)
---
05
Normal input 5
---
---
High-speed counter 2
(phase-B, decrement, or
direction input)
---
06
Normal input 6
---
---
High-speed counter 1
(phase-A, increment, or
count input)
---
07
Normal input 7
---
---
High-speed counter 1
(phase-B, decrement, or
direction input)
---
08
Normal input 8
---
---
High-speed counter 0
(phase-A, increment, or
count input)
---
09
Normal input 9
---
---
High-speed counter 0
(phase-B, decrement, or
direction input)
---
10
Normal input 10 ---
---
High-speed counter 3
(phase-A, increment, or
count input)
---
11
Normal input 11 ---
---
High-speed counter 3
(phase-B, decrement, or
direction input)
---
CIO 1
00
Normal input 12 Interrupt input 4
Quick-response
input 4
High-speed counter 3
(phase-Z/reset)
Pulse output 2: Origin
input signal
01
Normal input 13 Interrupt input 5
Quick-response
input 5
---
Pulse output 2: Origin
proximity input signal
02
Normal input 14 Interrupt input 6
Quick-response
input 6
---
Pulse output 3: Origin
input signal
03
Normal input 15 Interrupt input 7
Quick-response
input 7
---
Pulse output 3: Origin
proximity input signal
04
Normal input 16 ---
---
---
---
05
Normal input 17 ---
---
---
---
06
Normal input 18 ---
---
---
---
07
Normal input 19 ---
---
---
---
08
Normal input 20 ---
---
---
---
09
Normal input 21 ---
---
---
---
10
Normal input 22 ---
---
---
---
11
Normal input 23 ---
---
---
---
Summary of Contents for CP1H-CPU - 05-2006
Page 2: ...CP1H X40D CP1H XA40D CP1H Y20DT D CP1H CPU Unit Operation Manual Revised May 2006...
Page 3: ...iv...
Page 11: ...xii TABLE OF CONTENTS...
Page 15: ...xvi...
Page 19: ...xx...
Page 31: ...xxxii Conformance to EC Directives 6...
Page 71: ...40 Function Blocks Section 1 5...
Page 133: ...102 Computing the Cycle Time Section 2 7...
Page 169: ...138 CPM1A Expansion I O Unit Wiring Section 3 6...
Page 411: ...380 Clock Section 6 8...
Page 519: ...488 Replacing User serviceable Parts Section 10 2...
Page 527: ...496 Standard Models Appendix A...
Page 535: ...504 Dimensions Diagrams Appendix B...
Page 628: ...597 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Page 629: ...598 Connections to Serial Communications Option Boards Appendix F...
Page 659: ...628 PLC Setup Appendix G...
Page 665: ...634 Index work words 159 write protection 370...