Windows Setup and Operation 3-3
[Cautions for using the RDR function]
1.
RDR can be set only to the disks inserted into the built-in slots of NEC Express5800/ft series.
2.
Be sure to specify RDR to all disks inserted to the built-in slots and make duplex settings.
3.
RDR can be set only to basic disks.
If a span volume or stripe volume is needed, make settings of RDR to a basic disk and then
change the disk to a dynamic disk from [Disk Management].
4.
The disks to set RDR must have the same capacity and must be new or physically formatted.
(For physical format, refer to “SAS BIOS” in Chapter 4 and perform Format Disk using
Disk Utilities.)
5.
If the system is shut down (or restarted) while the mirror is broken, or a long time (30 minutes
or longer) has passed after the mirror is broken, the mirror resynchronization target will be the
entire disk.
For example, if the mirroring has been broken due to a PCI module failure, when you shut
down the system and replace the PCI module in such a state, the entire area of the disk needs
to be resynchronized.
6.
You must insert a new disk or replace a disk while the server is powered on.
7.
Create a data disk partition after configuring the RDR. If you create a data disk partition
before configuring the RDR, the partition’s drive letters may be deleted when the RDR is
configured.
Summary of Contents for Express5800/320Fd-MR
Page 13: ...v Appendix B I O Port Addresses This appendix lists factory assigned I O port addresses...
Page 19: ...xi THIS PAGE IS INTENTIONALLY LEFT BLANK...
Page 43: ...2 10 General Description Rear View...
Page 47: ...2 14 General Description CPU IO Module CPU IO module...
Page 67: ...2 34 General Description This page is intentionally left blank...
Page 79: ...3 12 Windows Setup and Operation 3 Confirm that RDR of the disk is cancelled...
Page 106: ...Windows Setup and Operation 3 39 This page is intentionally left blank...
Page 198: ...4 92 System Configuration This page is intentionally left blank...
Page 370: ......
Page 371: ...This page is intentionally left blank...
Page 389: ...6 18 Maintenance 3 Stop of PCI module 1 4 Start of PCI module 1...
Page 391: ...6 20 Maintenance This page is intentionally left blank...
Page 465: ...System Upgrade 8 31 board must not be mixed with N8804 005 or N8803 035...
Page 480: ......
Page 483: ......