4-88 System Configuration
BMC configuration errors
No. Error
message
Action
1
Failed to make settings:
Check the network environment and try again.
Contact your service representative if the error
persists.
2
Failed to acquire BMC
Configuration:
Check the network environment and try again.
Contact your service representative if the error
persists.
3
Used by other software program.
Try again after a while.
Try again after a while.
4
Invalid BMC configuration file.
The BMC configuration file may be corrupted. Check
the file.
5
The required XML tag is not
found.
The BMC configuration file may be corrupted. Check
the file.
6
Failed to write the file.
The BMC configuration file is not saved successfully.
Change the location to save the file and try again.
7
Invalid user name
You can use only alphanumeric characters, minus
sign (–), and underscore (_) for a user name. A user
name should be 31 characters or less.
8
The user name is too long
A user name should be 31 characters or less.
9
The password is too long.
Use 16 or less characters.
10
Passwords are not matched.
Enter passwords again.
11
Invalid HTTP port number
You can only use numeric values.
12
Invalid SSL port number
You can only use numeric values.
13
HTTP/SSL should not be the
same.
The same port number cannot be specified for HTTP
and SSL. Specify different value.
14
Invalid login attempt period
You can only use numeric values.
15
Invalid failed login attempts
You can only use numeric values.
16
Invalid account lock period
You can only use numeric values.
17
Invalid IP address
Use numbers and periods to specify an IP address.
18
Invalid subnet mask
Use numbers and periods to specify a subnet mask.
19
Invalid default gateway
Use numbers and periods to specify a default
gateway.
20
Invalid DNS server IP address
Use numbers and periods to specify the IP address of
DNS server.
Summary of Contents for Express5800/320Fd-MR
Page 13: ...v Appendix B I O Port Addresses This appendix lists factory assigned I O port addresses...
Page 19: ...xi THIS PAGE IS INTENTIONALLY LEFT BLANK...
Page 43: ...2 10 General Description Rear View...
Page 47: ...2 14 General Description CPU IO Module CPU IO module...
Page 67: ...2 34 General Description This page is intentionally left blank...
Page 79: ...3 12 Windows Setup and Operation 3 Confirm that RDR of the disk is cancelled...
Page 106: ...Windows Setup and Operation 3 39 This page is intentionally left blank...
Page 198: ...4 92 System Configuration This page is intentionally left blank...
Page 370: ......
Page 371: ...This page is intentionally left blank...
Page 389: ...6 18 Maintenance 3 Stop of PCI module 1 4 Start of PCI module 1...
Page 391: ...6 20 Maintenance This page is intentionally left blank...
Page 465: ...System Upgrade 8 31 board must not be mixed with N8804 005 or N8803 035...
Page 480: ......
Page 483: ......