Troubleshooting 7-5
On-screen error message
Cause
Action
0251 System CMOS
checksum bad-Default
configuration used
System CMOS configuration
is changed.
•
Reconfigure the system CMOS
by using BIOS setup.
•
Clear system CMOS using
hardware jumper.
0252 Password checksum
bad -Password cleared
Password is cleared.
•
Reconfigure by using BIOS
setup.
•
Clear system CMOS using
hardware jumper.
0260 System Timer error
System Timer is faulty.
0270 Real time clock error
RTC is faulty.
0271 Check date and time
setting
Date and time are incorrectly
set.
Reconfigure by using BIOS setup.
If the error cannot be solved after
this, replace the CPU/IO module.
02D0 System cache error -
Cache disabled
CPU cache is faulty.
02D1 System Memory
exceeds the CPU's
caching limit
CPU cache is faulty.
If replacing the CPU does not
help, replace the CPU/IO module.
0613 COM A configuration
change
COM A configuration is
faulty.
0614 COM A config, error -
device disable
Device constructing COM A
is faulty.
0615 COM B configuration
change
COM B configuration is
faulty.
0616 COM B config, error -
device disable
Device constructing COM A
is faulty.
If restarting does not help after
resetting the setting to default by
using BIOS setup, replace the
CPU/IO module.
0B28 Unsupported Processor
detected on Processor 1
Unsupported CPU is
mounted.
0B29 Unsupported Processor
detected on Processor 2
Unsupported CPU is
mounted.
Check the supported CPU and
replace it. If this does not help,
replace the CPU/IO module.
0B80 BMC Memory Test
Failed
RMC device is faulty.
0B81 BMC Firmware Code
Area CRC check failed
Replace the CPU/IO module.
0B82 BMC core Hardware
failure
0B83 BMC IBF or OBF check
failed
RMC device is faulty.
Replace the CPU/IO module.
0B8B BMC progress check
timeout
BMC check is suspended.
Replace the CPU/IO module.
0B8C BMC command access
failed
BMC command access
failed.
Replace the CPU/IO module.
0B90 BMC Platform
Information Area
corrupted
0B91 BMC update firmware
corrupted
BMC device is faulty.
Replace the CPU/IO module.
0B92 Internal Use Area of
BMC FRU corrupted
Data within SROM is faulty.
Replace the system backboard.
0B93 BMC SDR Repository
empty
SDR data is faulty.
If updating SDR does not help,
replace the CPU/IO module.
Summary of Contents for Express5800/320Fd-MR
Page 13: ...v Appendix B I O Port Addresses This appendix lists factory assigned I O port addresses...
Page 19: ...xi THIS PAGE IS INTENTIONALLY LEFT BLANK...
Page 43: ...2 10 General Description Rear View...
Page 47: ...2 14 General Description CPU IO Module CPU IO module...
Page 67: ...2 34 General Description This page is intentionally left blank...
Page 79: ...3 12 Windows Setup and Operation 3 Confirm that RDR of the disk is cancelled...
Page 106: ...Windows Setup and Operation 3 39 This page is intentionally left blank...
Page 198: ...4 92 System Configuration This page is intentionally left blank...
Page 370: ......
Page 371: ...This page is intentionally left blank...
Page 389: ...6 18 Maintenance 3 Stop of PCI module 1 4 Start of PCI module 1...
Page 391: ...6 20 Maintenance This page is intentionally left blank...
Page 465: ...System Upgrade 8 31 board must not be mixed with N8804 005 or N8803 035...
Page 480: ......
Page 483: ......