Troubleshooting 7-11
TROUBLESHOOTING
When the server fails to operate as expected, see the following to find out your problem and follow
the given instruction before asking for repair.
If the server still fails to operate successfully after solving your problem, take a note on the
on-screen message and contact your sales agent.
Problems with NEC Express5800/ft series
Fail to power on the server:
Is the server properly supplied with power?
→
Check if the power cord is connected to a power outlet (or UPS) that meets the
power specifications for the server.
→
Check if the two pieces of the provided power cord are connected to the main unit
properly.
→
Make sure to use the power cord provided with the server. Check the power cord
for broken shield or bent plugs.
→
Make sure the power breaker for the connected power outlet is on.
→
If the power cord is plugged to a UPS, make sure the UPS is powered and it
supplies power. See the manual that comes with the UPS for details.
Power supply to the server may be linked with the connected UPS using the BIOS
setup utility of the server.
<Menu to check: [Server] - [AC-LINK] - [Power On]>
→
Make sure the POWER switch on the power unit is on.
Did you press the POWER switch?
→
Press the POWER switch on the front of the NEC Express5800/ft series to turn on
the power (the POWER LED lights).
Did you install the CPU/IO module properly?
→
Check if the CPU/IO module is properly installed in the server. Secure the
CPU/IO module with screw located on the module removable handle.
The screen turns blue during OS boot:
→
Wait for the period of time you set at BIOS [Boot Monitoring]; after the boot
module is automatically swapped, the server will be rebooted and the OS will start
up.
Summary of Contents for Express5800/320Fd-MR
Page 13: ...v Appendix B I O Port Addresses This appendix lists factory assigned I O port addresses...
Page 19: ...xi THIS PAGE IS INTENTIONALLY LEFT BLANK...
Page 43: ...2 10 General Description Rear View...
Page 47: ...2 14 General Description CPU IO Module CPU IO module...
Page 67: ...2 34 General Description This page is intentionally left blank...
Page 79: ...3 12 Windows Setup and Operation 3 Confirm that RDR of the disk is cancelled...
Page 106: ...Windows Setup and Operation 3 39 This page is intentionally left blank...
Page 198: ...4 92 System Configuration This page is intentionally left blank...
Page 370: ......
Page 371: ...This page is intentionally left blank...
Page 389: ...6 18 Maintenance 3 Stop of PCI module 1 4 Start of PCI module 1...
Page 391: ...6 20 Maintenance This page is intentionally left blank...
Page 465: ...System Upgrade 8 31 board must not be mixed with N8804 005 or N8803 035...
Page 480: ......
Page 483: ......