Troubleshooting 7-43
COLLECTING THE MEMORY DUMP
If a failure occurs, the memory data should be dumped to acquire the required information. If you
stored the dump data in a DAT, label it so as to indicate the software (e.g. NTBackup) you used for
storing it. You may save the diagnosis data to a desired destination.
IMPORTANT:
Consult with your sales agent before dumping the memory. Executing memory dumping
while the server is in the normal operation may affect the system operation.
Restarting the system due to an error may display a message indicating insufficient virtual
memory. Ignore this message and proceed. Restarting the system again may result in
dumping improper data.
Press the DUMP switch on the primary CPU/IO module, whose POWER LED has been
blinking, for four to eight seconds. Use something sharp, such as curved clips to press the
DUMP switch on CPU/IO module 1.
Preparing to collect Memory Dump
Memory dumping with the DUMP switch may disable the server to restart. In such a case, it is
required to force the server to shut down.
Saving Dump Files
Press the DUMP (NMI) switch on the primary
CPU/IO module to save the dump file when an
error occurs. Insert something sharp-pointed like a
pen into the switch hole to press the DUMP
switch.
Pressing the DUMP switch saves the dump file in
the specified directory. (Memory dumping may
not be available when the CPU stalls.)
IMPORTANT:
Do not use a toothpick or plastic
stick that is easy to break.
DUMP (NMI) switch
Summary of Contents for Express5800/320Fd-MR
Page 13: ...v Appendix B I O Port Addresses This appendix lists factory assigned I O port addresses...
Page 19: ...xi THIS PAGE IS INTENTIONALLY LEFT BLANK...
Page 43: ...2 10 General Description Rear View...
Page 47: ...2 14 General Description CPU IO Module CPU IO module...
Page 67: ...2 34 General Description This page is intentionally left blank...
Page 79: ...3 12 Windows Setup and Operation 3 Confirm that RDR of the disk is cancelled...
Page 106: ...Windows Setup and Operation 3 39 This page is intentionally left blank...
Page 198: ...4 92 System Configuration This page is intentionally left blank...
Page 370: ......
Page 371: ...This page is intentionally left blank...
Page 389: ...6 18 Maintenance 3 Stop of PCI module 1 4 Start of PCI module 1...
Page 391: ...6 20 Maintenance This page is intentionally left blank...
Page 465: ...System Upgrade 8 31 board must not be mixed with N8804 005 or N8803 035...
Page 480: ......
Page 483: ......