7-38 Troubleshooting
Network drive is not displayed in the data viewer:
→
On WindowsXP or the OS released after it, the drive connected to network is not
displayed under the file system tree in the data viewer of NEC ESMPRO
Manager.
Shutdown monitoring:
→
When performing shutdown monitoring, all shutdown processes are to be
monitored. If there is an application that performs shutdown without rebooting OS
or turning off the power, set the timeout value longer or disable the monitoring
function.
The external clock of CPU is listed as “Unknown”:
→
In [CPU information] of Data Viewer’s system tree, the external clock is listed as
“Unknown.”
[ft] tree appears on data viewer in an incorrect manner:
→
After the system starts up, the tree or the state of a Data Viewer may not be
displayed correctly due to high load of the system. In about 20 minutes after the
system startup, when a pop-up message which prompts you to reconstruct a Data
Viewer appears, click [OK]. The Data Viewer will be reconstructed and the tree
and the status will be displayed correctly.
The information on the floppy disk appears in an incorrect manner:
→
After switching on and off the power of the CPU/IO module, the floppy disk drive
name of [I/O Device] on Data Viewer may be different from the name that is
recognized by the OS.
(Example: drive name on Data Viewer: “A”
drive name recognized by the OS “B”)
Check the floppy disk drive name on Explorer.
→
If you add or delete floppy disk drive connected with USB while the system is
running, the drive information under the [I/O Device] in the data viewer will be
updated at the next system startup.
When the Displayed BIOS Information is Incorrect
Additional information of BIOS which is displayed by clicking [ft] - [CPU Module] - a CPU
module - [General] - [BIOS Information] on a Data Viewer or by clicking a CPU module and
clicking [BIOS Information] on ftServer Utility may not be displayed correctly. In such a case,
display the BIOS information on a Data Viewer by clicking [ESMMIB] - [BIOS].
Summary of Contents for Express5800/320Fd-MR
Page 13: ...v Appendix B I O Port Addresses This appendix lists factory assigned I O port addresses...
Page 19: ...xi THIS PAGE IS INTENTIONALLY LEFT BLANK...
Page 43: ...2 10 General Description Rear View...
Page 47: ...2 14 General Description CPU IO Module CPU IO module...
Page 67: ...2 34 General Description This page is intentionally left blank...
Page 79: ...3 12 Windows Setup and Operation 3 Confirm that RDR of the disk is cancelled...
Page 106: ...Windows Setup and Operation 3 39 This page is intentionally left blank...
Page 198: ...4 92 System Configuration This page is intentionally left blank...
Page 370: ......
Page 371: ...This page is intentionally left blank...
Page 389: ...6 18 Maintenance 3 Stop of PCI module 1 4 Start of PCI module 1...
Page 391: ...6 20 Maintenance This page is intentionally left blank...
Page 465: ...System Upgrade 8 31 board must not be mixed with N8804 005 or N8803 035...
Page 480: ......
Page 483: ......