T320 Honeywell Server Planning, Installation and Service

Guide

HWDOC-X239-en-I

     August

2

020

Summary of Contents for T320

Page 1: ...T320 Honeywell Server Planning Installation and Service Guide HWDOC X239 en I August 2020 ...

Page 2: ...al Sàrl While this information is presented in good faith and believed to be accurate Honeywell disclaims the implied warranties of merchantability and fitness for a purpose and makes no express warranties except as may be stated in its written agreement with and for its customer In no event is Honeywell liable to anyone for any direct special or consequential damages The information and specifica...

Page 3: ... 3 2 Dell documentation 15 2 4 LCN node slot requirements 17 2 5 Experion nodes slot requirement 17 2 5 1 Default configurations for FTE 17 2 5 2 FTE supervisory Default 17 2 5 3 Cnet configuration using PCIC interface 18 2 6 Memory configuration for Dell T320 18 2 6 1 4GB consisting of two 2GB RDIMM for Pre MLK servers 19 2 6 2 8GB consisting of four 2GB RDIMM or two 4GB RIDMM for Pre MLK servers...

Page 4: ...etic Compatibility 28 2 9 2 Safety compliance 29 Chapter 3 Installation 30 3 1 Tasks for installing the server 30 3 1 1 Before you begin 30 3 2 Power and grounding requirements 30 3 2 1 Grounding consoles and cabinets 31 3 3 Cabinet spacing requirements 31 3 3 1 Unused cabinet spaces 31 3 4 Installing Dell T320 server and connecting cables 32 3 4 1 Honeywell server back panel connections 32 3 4 2 ...

Page 5: ... 1 1 To remove the front bezel 49 5 2 Removing the side cover 50 5 2 1 To remove the side cover 50 5 3 Servicing the LCNP4e LCNP4e2 51 5 3 1 Replacing the LCNP4e LCNP4e2 board 51 5 4 Servicing the hard disk drives and power supply 53 5 4 1 References 53 5 5 Servicing Honeywell options 54 5 5 1 LCN node slot requirements 54 5 5 2 Slot requirements for General Ethernet and FTE node setup 55 5 6 Addi...

Page 6: ...ettings for Tab 51155517 300 71 5 9 5 BIOS settings for Tab 51155517 400 76 5 9 6 BIOS settings for Tab 51155517 500 83 5 9 7 BIOS settings for Tab 51155517 600 88 5 9 8 Exiting the BIOS 94 5 10 Spare parts 94 5 11 Troubleshooting 95 5 11 1 Integrated Dell Remote Access Controller 6 iDRAC6 issue 95 6 ...

Page 7: ...face to LCN is not used The LCN MAU is disconnected and or the LCNP board is removed Redundant ELCN Bridges are required if the ELCN node is communicating with any other existing coaxial based LCN node Some LCN nodes may have been replaced by their ELCN equivalent nodes and overall system features architecture will differ from that of a non ELCN integrated system classic LCN TPN system In this cas...

Page 8: ...scribes configuration tasks needed for TPS Nodes Virtualization Planning and Implementation Guide EPDOC X147 en A Implementing networks Preparing ESXi host Administering virtualization Server and Client Planning Guide EPDOC X128 en 511A High level planning design for Experion servers clients controllers Process Operations Manual SW11 601 Process operations alarm message handling reporting history ...

Page 9: ...ssues special considerations Customer Release Guide R687 CRG 687 TPN TPS Migration information ELCN migration Information included TPN R687 Software Change Notice TNDOC X166 en 6871A Document changes compatibility and migration installation processes for the TPS Process Network Release of R687 software Experion Control Building User s Guide EPDOC XX19 en 511A Procedures for basic tasks in the Cont...

Page 10: ...Notice SCN The server is not a standard Dell model and cannot be ordered independently from Dell The Technical Assistance Center TAC is well trained and supports Honeywell platforms Use of any other server including a similar Dell model is considered a project special and its TAC support is limited according to the services policy The Dell PowerEdge T320 server are shipped with the following Tab n...

Page 11: ...work on APP Nodes and ACE T nodes 2 1 2 BIOS configuration The BIOS version for the server depends on the Tab numbers The Tab numbers for Dell PowerEdge T320 server are l 51155517 100 with BIOS version 1 3 5 Honeywell 1 0 0 l 51155517 200 with BIOS version 1 3 5 Honeywell 1 0 0 l 51155517 300 with BIOS version 1 3 5 Honeywell 1 0 0 l 51155517 400 with BIOS version 2 0 22 or later l 51155517 500 wi...

Page 12: ...ce Edition 51155517 600 MZ PCEH03 146 GB 2 5 15K RPM SAS HDD with 3 5 bay or 300 GB 3 5 15K RPM SAS HDD to use as a Hot Spare if the hot spare is required then you need to buy it as it is not supplied with the standard configuration obsolete 51155517 905 MZ PCEH07 300 GB 3 5 15K RPM SAS HDD to use as a Hot Spare if the hot spare is required then you need to buy it as it is not supplied with the st...

Page 13: ...D 5 Edition l Intel Xeon E5 2430 2 20 GHz 15 M Cache 4 GB RDIMM 2x2 GB 146 GB 15K RPM Serial Attach SCSI 6 Gbps 2 5 in Hot plug Hard Drive QTY 4 H710 Controller RAID 5 configuration Following are the list of common features of MLK servers l Dell motherboard with Single Intel Xeon E5 2403V2 1 80 GHz CPU 12 M Cache Memory 6 4 GT s QPI 8 GB RDIMM 2x4 GB 500 GB Serial ATA Hard disk l Intel Xeon E5 240...

Page 14: ...nfiguration An onboard dual NIC is available for FTE and an optional single port NIC is available for EHG application The single NIC model number is as follows Model number Description TP LCNP04 LCN Interface card PCIE LCNP4e LCNP4e2 TP LCNP05 LCN Interface card PCIE LCNP4e LCNP4e2 NOTE A Local Control Network Processor LCNP board and LCN Media Access Unit MAU are no longer used if the Server has ...

Page 15: ...tation The following table lists the Honeywell publications that may be useful when installing or operating your system Publication Contains information about Fault Tolerant Ethernet Installation and Service Guide Installing and using FTE on a TPS or Experion PKS node 2 3 2 Dell documentation The following table lists the Dell publications that may be useful when installing or operating the system...

Page 16: ...stems Hardware Owner s Manual Removing and replacing the parts Technical specifications Configuring the system Troubleshooting Product Documentation CD www dell com Rack Installation Instructions Sliding Rails Installing the server in a server rack or cabinet Packaged with the computer www dell com Windows Installation Instructions and Important Information Initialization the Windows operating sys...

Page 17: ... MZ PCSV73 NOTE A Local Control Network Processor LCNP board and LCN Media Access Unit MAU are no longer used if the Server has been upgraded to be an ELCN node 2 5 Experion nodes slot requirement 2 5 1 Default configurations for FTE l Broadcom on board NICs are enabled without PXE l If you are using FTE slot only then use on board NICs l FTE supervisory Default l Cnet configuration using PCIC int...

Page 18: ...Ie_G2x4 Free Slot Slot 2 PCIe_G2x1 Free Slot Slot 3 PCIe_G3 x16 _CPU1 Magma Host Card Slot 4 PCIe_G3x4_CPU1 Free Slot Slot 5 PCIe_G3x16_CPU2 Free Slot Slot 6 PCIe_G3x4_CPU1 Empty for MZ PCSV71 PERC H310 Controller for MZ PCSV72 PERC H710 Controller for MZ PCSV73 2 6 Memory configuration for Dell T320 Standard memory for all the three variants of Dell T320 MLK server is 8GB 2x4GB RDIMM 1333MHz or f...

Page 19: ...0 uses Intel Xeon E5 2430V2 2 50GHz l 4GB consisting of two 2GB RDIMM for Pre MLK servers l 8GB consisting of four 2GB RDIMM or two 4GB RIDMM for Pre MLK servers l 8GB consisting of two 4GB RIDMM for MLK servers 2 6 1 4GB consisting of two 2GB RDIMM for Pre MLK servers The following table provides memory configurations layout for 4GB consisting of two 2GB RDIMM 1333 MHz DIMM socket Memory size Tot...

Page 20: ...available for use A4 Not available for use A2 4GB A5 A3 4GB A6 8GB In order to support R50x x release customer needs to remove existing 2GB Memory Modules and use 4 modules of MZ PCEM20 and make server to 16GB please refer table 2 6 3 for more details Population will be as follows DIMM socket Memory size Total memory A1 Not available for use A4 Not available for use A2 4GB A5 4GB A3 4GB Z6 4GB 16G...

Page 21: ... W for Tab 400 500 l Intel Xeon E5 2430V2 2 50 GHz 15M Cache 7 2GT s QPI Turbo 6C 95 W for Tab 600 Intel Smart Cache Intel Xeon E5 2403 1 80 Ghz 10M Cache Intel Xeon E5 2430 2 20 GHz 15M Cache Intel Xeon E5 2403V2 1 80 Ghz 10M Cache Intel Xeon E5 2430V2 2 50 GHz 15M Cache Chipset Intel C600 PCIe slots 5 PCIe slots 1x16 slot with x16 bandwidth 3 0 full height full length 1x8 slot with x4 bandwidth ...

Page 22: ...D Tab 300 Tab 600 PERC H710 mini controller RAID 5 configuration 4 HDD on RAID 2 7 4 Optical disk drive DVD drive SATA DVD R W 2 7 5 Video Video type Matrox G200e Controller 2 7 6 Network interface Adapter type Broadcom 5720 Dual Port 1Gb LOM 2 7 7 Power The following provides the specifications for DC power supply Wattage Tab 100 Tab 400 Energy Smart Single Power Supply 350W Tab 200 500 Energy Sm...

Page 23: ...ct sunlight is not allowed Operating humidity 20 to 80 non condensing with a maximum humidity gradation of 10 per hour Storage humidity 5 to 95 non condensing with a maximum humidity gradation of 10 per hour ATTENTION Storing maximum humidity of 95 is based on a maximum temperature of 45 C 113 F Altitude maximum for storage corresponds to a pressure minimum of 70 KPa Airborne Contaminants Airborne...

Page 24: ...ysical form factor Height 471 3 mm Width 307 9 mm Depth 594 4 mm Weight Maximum Config 29 55 KGs 65 00lb 2 7 10 Drive bays Internal 8 x 3 5 hot plug External Optical drive 2 7 11 Maximum vibration Operating 0 26 Grms at 5 Hz to 350 Hz in all orientations Storage 1 87 Grms at 10 Hz to 500 Hz for 15 minutes all six sides tested by Dell 2 7 12 Shock Operating Half sine shock in all operational orient...

Page 25: ... 3 5in Hot plug Hard Drive RAID 5 configuration Tab 300 600 4 x 146 GB 2 5 inch or 300 GB 3 5 inch SAS 15K RPM hot plug drives hard drives 0 1 2 and 3 are in a RAID 5 configuration with hard drive 4 as a hot spare drive customer need to buy Hot spare separately 2 7 16 External ports Serial One DB 9 connectors LAN 2 x RJ 45 SCSI External None USB Five USB 4 pin ports USB 2 0 Two in front Two in rea...

Page 26: ...AC Power N A The following table provides the maximum weight and dimensions for 146 GB hard drive Description Requirement Height 14 81 mm Width 70 mm Depth 100 5 mm Weight 0 201 kg 2 7 19 Removable media specifications The Honeywell based Dell T320 server has one SATA DVD RW drive The SATA DVD RW drive is connected to the SATA connector on the motherboard DC 5 volt power 6 5 Watts is the operating...

Page 27: ...DDC is attached to the server platform the display generator defaults to a resolution which precludes communication with the system software and stops startup To determine if a cable is DDC compatible ensure that pins 5 9 and 12 of the HD15 connector are wired The IS supplied cable 51196742 200 is DDC compatible 2 8 Industrial regulatory compliance The compliance specifications in this section app...

Page 28: ...9 and 1010 1B 97 R2001 Am 2 l IEC 61010 1 2001 2nd edition ATTENTION In the above referenced standards is a Normative Reference section citing additional standards which may apply as suited and required for product compliance 2 9 Light industrial regulatory compliance The compliance specifications in this section apply to installations other than cabinets ATTENTION Honeywell does not claim Safety ...

Page 29: ...ivers walkie talkies in Watts Examples P 10 Watts D 0 949 meters P 5 Watts D 0 671 meters P 1 Watt D 0 300 meters Electrical cables which are routed external to the equipment must be fully shielded cables 360 degree metallic shielding to comply with the above EMC standards 2 9 2 Safety compliance The following are the light industrial regulatory product safety compliance l CSA C22 2 No 1010 1 92 R...

Page 30: ...hecklist Tasks Understanding the Power and grounding requirements Also refer to TPN System Installation Guide SW20 600 Installing the server and connecting the cables Starting the server l Before you begin 3 1 1 Before you begin Ensure that you perform the following tasks l Ensure that the cabinet is properly grounded l Unpack the platform from the box and verify the parts l Place the server on a ...

Page 31: ...l constraints only one Dell T320 can be mounted on a new build 1 meter deep Honeywell MP C1MCB1 cabinet The server must be mounted on rack space interval 11U through 15U counting from the bottom of the cabinet and moving up Install a 1U air duct baffle and blank front panel in the rails directly above the server The room ambient temperature must be kept between 10 dm and 30 dm C 50 dm to 86 dm F 3...

Page 32: ...he Honeywell factory with either the fixed rail mounting kit model number TP SPCMF1 or the slide tray mounting kit model number TP SPCMS1 pre installed NOTE A Local Control Network Processor LCNP board and LCN Media Access Unit MAU are no longer used if the Server has been upgraded to be an ELCN node l Honeywell server back panel connections l Installing the server using the fixed rail mounting ki...

Page 33: ...NOTE The photo shows the MAU connector attached to the server back panel The LCN MAU is not used when the LCN is integrated with an ELCN 33 Chapter 3 Installation ...

Page 34: ...d right front retaining brackets 3 The rear retaining bracket is located in a slot in the rear of the left side mounting bracket when viewed from the front of the cabinet Position the rear retaining bracket approximately 83 mm 3 25 inches forward of the rear edge of the left side mounting bracket 4 Measure the distance between the inside surfaces of the left and right side mounting brackets should...

Page 35: ...SPCMS1 This procedure is the same regardless of whether the cabinet is 800 or 1000 mm deep Do NOT remove the plastic feet from the bottom of the server when oriented as a tower This installation procedure intentionally omits use of the server front bezel cover This is done to allow the front retaining brackets to bear against a flat surface If the server front bezel is required for security reason...

Page 36: ...inches forward of the rear surface of the slide tray 5 Remove the plastic film release liners from the two 2 front and two 2 rear black anti skid pads on the slide mounting tray This exposes a tacky surface that helps prevent the server from sliding 6 The photo shows the MAU connector attached to the server back panel The LCN MAU is not used when the LCN is integrated with an ELCN 36 ...

Page 37: ...hten the two captivated panel fasteners in each front retainer bracket into the threaded standoffs protruding from the side brackets c Adjust the stop peg on each front retainer bracket so it is in contact with the server front bezel as shown above Tighten the stop peg hex standoffs 3 4 4 Connecting the cables To connect the cables 37 Chapter 3 Installation ...

Page 38: ...lot l If you are using the on board NICs for FTE connect the FTE cable to the onboard RJ 45 connector 4 Secure any loose cables and verify that all cables have proper strain relief 5 If necessary refer to the section Install air duct baffles and blank panel front covers in cabinet ATTENTION Any unused rack mount space must have an air duct baffle and blank front panel installed 6 To complete the i...

Page 39: ...anel front covers in cabinet 1 Place the air duct baffle inside the cabinet with the bent tab resting along the front of the right cabinet rail Figure 3 2 Installation of Air Duct Baffle and Blank Panel Front Cover 39 Chapter 3 Installation ...

Page 40: ...o the rear cabinet rail using two thread forming screws and two external tooth washers and tighten the screws 5 Attach the air duct baffle to the rear mounting bracket using two machine screws and two external tooth washers threaded into the two self clinching nuts Tighten the screws 3 5 Starting the server l Turning on the power l Configuring RAID in Dell T320 server l Starting the TDC emulator s...

Page 41: ...ollowing l For MZ PCSV72 select Controller H 310 l For MZ PCSV73 select Controller H 710 8 Press F2 to display the menu of available actions 9 Select Create New VD and press ENTER The Create New VD screen appears The cursor is on the RAID Level option 10 Press ENTER to display the RAID levels 11 Select a RAID 5 using the arrow keys and then press ENTER 12 Press the TAB key and then move the cursor...

Page 42: ...s msc The Services page appears 3 Right click TDC Emulator service and click Start 3 5 4 Checking the LCNP4e LCNP4e2 status If this is an Experion T node or a TPS node with the LCNP4E board installed perform the following steps to verify the LCNP4e LCNP4e2 passed self test To check the LCNP4e LCNP4e2 status 1 Choose Start Programs Honeywell TPS LCNP Status 2 Verify that the LCNP status indicates P...

Page 43: ...ew of the Dell T320 server for MZ PCSV72 and MZ PCSV73 These servers are provided with 2 5 inch Hot swappable hard drive chassis Figure 4 1 Front panel with 2 5 inch Hot swappable hard drive chassis The following image illustrates the front view of the Dell T320 server for MZ PCSV71 This server is provided with 3 5 inch Hot swappable hard drive chassis Figure 4 2 Front panel with 3 5 inch Hot swap...

Page 44: ... 3 Optical drive 1 optional 4 Power on indicator power button 5 NMI button 6 System identification button 7 LCD menu buttons 8 Information tag 9 LCD panel 10 USB connectors 2 11 Hard drives 4 1 2 Rear view of Dell T320 The following image illustrates the rear view of the Dell T320 server 44 Chapter 4 Operation ...

Page 45: ... identification connector 7 USB connectors 6 8 Ethernet connectors 2 9 Video connector 10 Serial connector 11 External cooling fan power cable slot 4 2 Network connections Each Honeywell configured platform must be connected to an ETHERNET network NOTE A Local Control Network Processor LCNP board and LCN Media Access Unit MAU are no longer used if the Server has been upgraded to be an ELCN node l ...

Page 46: ...nsists of an LCNP4e LCNP4e2 Card a MAU cable and the LCN MAU Media Access Unit The LCNP4e LCNP4e2 card is a PCIe card and is located in PCI ex8 slot 1 The LCNP4e LCNP4e2 MAU and MAU cable are required on Server Platform The LCN node address must be set to the address the customer wants If the LCN address is not known then the node address must be set to zero 0 Setting the address to zero 0 allows ...

Page 47: ...ough a Tap and drop cable Repeaters are used to link segments together and for changes in media from coax to fiber optic All points on the network must either have an interface card or a terminator Terminators are comprised of termination resistors which are used to mark the beginning and end of a trunk segment and Tap Dummy Load TDL which terminate a drop cable when no node is present The model n...

Page 48: ... interface card using the Magma PE3R PCie to PCI converter box 1 For more information on the Magma PE3R PCie to PCI converter box log into honeywellprocess com 2 Enter your user name and password 3 Go to the Product Support section 4 Search for Magma PE3R instructions l Installing ControlNet card inside Magma chassis 4 3 1 Installing ControlNet card inside Magma chassis Refer to the Magma PE3R Ins...

Page 49: ...talling hot spare hard drive l Installing PCIC card in Dell T320 server using Magma l Verifying correct BIOS settings l Spare parts l Troubleshooting 5 1 Removing the front bezel 5 1 1 To remove the front bezel 1 Push the top lever in the direction of the arrow until it releases the bezel from the top of the chassis 2 Pull the bezel away from the chassis removing the bezel tabs from the slots 49 C...

Page 50: ...nstalls the components on the motherboard you must first remove the side cover 5 2 1 To remove the side cover 1 Press the release latch and lift it up as illustrated in the following 2 Lift the cover away from the system 50 Chapter 5 Servicing ...

Page 51: ...NP4e LCNP4e2 board The LCNP4e LCNP4e2 board is located in the PCIe slot 3 To replace the LCNP4e LCNP4e2 board NOTE If upgrading to an ELCN node perform Steps 1 through 8 to remove the LCNP4 board 1 Shut down the computer 2 Remove the power cords from the rear end of the server and wait for 20 seconds 3 Remove the front bezel Refer to the section Removing the front bezel 4 Remove the side cover of ...

Page 52: ...6 Press the card retainers blue plastic notch and push it back 7 Remove the metal shield adjacent to the LCNP4e LCNP4e2 card in PCIe slot 3 52 Chapter 5 Servicing ...

Page 53: ...and power supply The server from Honeywell is configured with five 146 GB or 300 GB SAS hard drives for RAID 5 configuration and the fifth hard drive is a hot spare The configuration also contains redundant power supplies Both the hard disk drives and power supplies are hot swappable and must be of same capacity and speed You must replace only one power supply and or hard disk drive at a time in a...

Page 54: ...Ports and Connectors Abbreviations and Acronyms 5 5 Servicing Honeywell options CAUTION Do not damage the EMI gasket fingers when removing installing boards WARNING Use a grounding strap and grounded work surfaces and equipment when handling any electro statically sensitive components such as the video cards NIC adapter cards and SCSI controller cards Store and transport parts only in electro stat...

Page 55: ...rements for General Ethernet and FTE node setup The following table identifies the specific slots for each of the Honeywell options for general Ethernet and FTE node configurations Configuration PCIE x 4 PCIE x 8 PCIE x 8 PCIE x 4 PCIE x 4 FTE Supervisory Default Free Slot Free Slot Free Slot Free Slot l Empty for MZ PCSV71 l PERC H310 Controller for MZ PCSV72 l PERC H710 Controller for MZ PCSV73 ...

Page 56: ... the section Memory configuration for Dell T320 5 6 1 Prerequisites l Turn off the system l Disconnecting power cords and cables from the server CAUTION The DIMMs are hot to the touch for some time after the system is powered down Allow time for the DIMMs to cool before handling them Handle the DIMMs by the edges and avoid touching DIMM components 5 6 2 To add additional memory 1 Remove the front ...

Page 57: ...ry module in the socket only in one way 8 Press down the memory module with your thumbs while pulling up on the socket ejectors with your index fingers to lock the memory module into the socket When the memory module is properly seated in the socket the socket ejectors on the memory module socket align with the socket ejectors on the other sockets that have memory modules installed 9 Place the shr...

Page 58: ...disk drives MZ PCEH02 are obsolete and Customer may receive Replacement as 300 GB MZ PCEH07 Hard disk drives These drives can be used in RAID5 array with 146 GB Hard disk drives Usable capacity of will remain 146 GB as it will be part of Array In case of multiple hard disk drives failure replacements you need to replace the spare hard disk drives one by one that is after rebuilding RAID volume by ...

Page 59: ...Chapter 5 Servicing 6 Press the card retainers blue plastic notch and push it back 7 Remove the metal shield in slot 3 59 ...

Page 60: ... slot 3 12 Replace the side cover and the front bezel 5 9 Verifying correct BIOS settings All Honeywell systems must have the Honeywell recommended BIOS version Honeywell configures specific BIOS settings in the factory for each of the server platform configurations and these settings must not be altered The following table provides the default BIOS settings for the server BIOS settings FTE only N...

Page 61: ...ab 51155517 600 l Exiting the BIOS 5 9 1 Entering the BIOS To enter the BIOS 1 Turn on the server 2 Press F2 on the keyboard to enter the BIOS Setup 3 Verify that the BIOS version 5 9 2 BIOS settings for Tab 51155517 100 System information Product name Dell PowerEdge T320 server System model name T320 001 BIOS Version 1 3 5 Honeywell 1 0 0 System manufacturer Dell System Manufacturer Contact info ...

Page 62: ...dvanced ECC Mode Node interleaving Disabled CPU information Alternate RTID Disabled Virtualization technology Enabled Adjacent cache prefetcher Enabled Hardware prefetcher Enabled DCU Steamer Prefetcher Enabled DCU IP Prefetcher Enabled Execute Disable Enabled Logical Processor Idling Disabled Number of Cores per processor All Processor 64 bit Support Yes Processor Core Speed 2 20 GHz 62 Chapter 5...

Page 63: ...A Mode PORT A B C D Auto Model Unknown Device type Unknown device Capacity N A PORT E Auto Model Refer to DVD R W model number Device type Unknown device Capacity N A Boot settings Boot Mode BIOS Boot Sequence Retry Disabled Boot sequence 1 Embedded SATA Port Optical Drive E 2 Hard Drive C 3 Embedded NIC Port 1 Partition 1 Partition 1 BRCM MBA Slot 0100 V15 2 10 Boot option Enable Disable 63 ...

Page 64: ...BIOS Boot Sequence Device Hard drive C BIOS Hard Disk Drive Sequence Device RAID Controller UFFI Boot Sequence Device Embedded NIC Integrated devices User Accessible USB Ports All Ports On Internal USB Port On Embedded NIC1 and NIC2 Enabled OS Watchdog Timer Disabled I O AT DMA Engine Disabled Embedded Video Controller Enabled SR 10V Globe Engine Disabled Slot 1 to Slot 6 Enabled 64 Chapter 5 Serv...

Page 65: ...erial Device 1 Fail Safe Baud Rate 115200 Remote Terminal Type VT100 VT220 Redirection After Boot Enabled System profile settings System profile Performance System security Intel AES NI Enabled System Password Setup Password Password Status Unlocked TPM Security Off TPM Activation No Change TPM Clear No Intel TXT Off Power Button Enabled NMI Button Disable AC Power Recovery Last 65 ...

Page 66: ... Selection LOM1 Failover Network None MAC Address XXXXXXXXXXXX Auto Negotiation On Network Speed 100 Mbps Duplex Mode Full Duplex 5 9 3 BIOS settings for Tab 51155517 200 System information Product name Dell PowerEdge T320 server System model name T320 001 BIOS Version 1 3 5 Honeywell 1 0 0 System manufacturer Dell System Manufacturer Contact info www dell com System CPLD version 100 or later 66 C...

Page 67: ...mory operating mode Advanced ECC Mode Node interleaving Disabled CPU information Alternate RTID Disabled Virtualization technology Enabled Adjacent cache prefetcher Enabled Hardware prefetcher Enabled DCU Steamer Prefetcher Enabled DCU IP Prefetcher Enabled Execute Disable Enabled Logical Processor Idling Disabled Number of Cores per processor All Processor 64 bit Support Yes Processor Core Speed ...

Page 68: ...uto Model Unknown Device type Unknown device Capacity N A PORT E Auto Model Refer to DVD R W model number Device type Unknown device Capacity N A Boot settings Boot Mode BIOS Boot Sequence Retry Disabled Boot sequence 1 Embedded SATA Port Optical Drive E 2 Hard Drive C 3 Embedded NIC Port 1 Partition 1 Partition 1 BRCM MBA Slot 0100 V15 2 10 Boot option Enable Disable 68 Chapter 5 Servicing ...

Page 69: ...e Boot Device List Disabled BIOS Boot Sequence Device Hard drive C BIOS Hard Disk Drive Sequence Device RAID Controller UFFI Boot Sequence Device Embedded NIC Integrated devices User Accessible USB Ports All Ports On Internal USB Port On Embedded NIC1 and NIC2 Enabled OS Watchdog Timer Disabled I O AT DMA Engine Disabled Embedded Video Controller Enabled SR 10V Globe Engine Disabled Slot 1 to Slot...

Page 70: ...Safe Baud Rate 115200 Remote Terminal Type VT100 VT220 Redirection After Boot Enabled System profile settings System profile Performance System security Intel AES NI Enabled System Password Setup Password Password Status Unlocked TPM Security Off TPM Activation No Change TPM Clear No Intel TXT Off Power Button Enabled NMI Button Disable AC Power Recovery Last 70 Chapter 5 Servicing ...

Page 71: ...AC Enable NIC Enabled NIC Selection LOM1 Failover Network None MAC Address XXXXXXXXXXXX Auto Negotiation On Network Speed 100 Mbps Duplex Mode Full Duplex 5 9 4 BIOS settings for Tab 51155517 300 System information Product name Dell PowerEdge T320 server System model name T320 001 BIOS Version 1 3 5 Honeywell 1 0 0 System manufacturer Dell System Manufacturer Contact info www dell com System CPLD ...

Page 72: ... ECC Mode Node interleaving Disabled CPU information Logical processor Enabled Alternate RTID Disabled Virtualization technology Enabled Adjacent cache prefetcher Enabled Hardware prefetcher Enabled DCU Steamer Prefetcher Enabled DCU IP Prefetcher Enabled Execute Disable Enabled Logical Processor Idling Disabled Number of Cores per processor All Processor 64 bit Support Yes Processor Core Speed 2 ...

Page 73: ...TA Mode PORT A B C D Auto Model Unknown Device type Unknown device Capacity N A PORT E Auto Model Refer to DVD R W model number Device type Unknown device Capacity N A Boot settings Boot Mode BIOS Boot Sequence Retry Disabled Boot sequence 1 Embedded SATA Port Optical Drive E 2 Hard Drive C 3 Embedded NIC Port 1 Partition 1 Partition 1 BRCM MBA Slot 0100 V15 2 10 Boot option Enable Disable 73 ...

Page 74: ...isabled BIOS Boot Sequence Device Hard drive C BIOS Hard Disk Drive Sequence Device RAID Controller UFFI Boot Sequence Device Embedded NIC Integrated devices User Accessible USB Ports All Ports On Internal USB Port On Embedded NIC1 and NIC2 Enabled OS Watchdog Timer Disabled I O AT DMA Engine Disabled Embedded Video Controller Enabled SR 10V Globe Engine Disabled Slot 1 to Slot 6 Enabled 74 Chapte...

Page 75: ...erial Device 1 Fail Safe Baud Rate 115200 Remote Terminal Type VT100 VT220 Redirection After Boot Enabled System profile settings System profile Performance System security Intel AES NI Enabled System Password Setup Password Password Status Unlocked TPM Security Off TPM Activation No Change TPM Clear No Intel TXT Off Power Button Enabled NMI Button Disable AC Power Recovery Last 75 ...

Page 76: ...NIC Selection LOM1 Failover Network None MAC Address XXXXXXXXXXXX Auto Negotiation On Network Speed 100 Mbps Duplex Mode Full Duplex 5 9 5 BIOS settings for Tab 51155517 400 System information Product name Dell PowerEdge T320 server System model name T320 001 BIOS Version 2 0 22 or later System manufacturer Dell System Manufacturer Contact info www dell com System CPLD version 100 or later 76 Chap...

Page 77: ...operating mode Advanced ECC Mode Node interleaving Disabled CPU information Alternate RTID Disabled Virtualization technology Enabled Adjacent cache prefetcher Enabled Hardware prefetcher Enabled DCU Steamer Prefetcher Enabled DCU IP Prefetcher Enabled Execute Disable Enabled Logical Processor Idling Disabled Number of Cores per processor All Processor 64 bit Support Yes Processor Core Speed 1 80 ...

Page 78: ...TTENTION During the Init Media installation if the installation is unresponsive change the ATA Drive setting from ATA Mode to AHCI Mode PORT A B C D Auto Model Unknown Device type Unknown device Capacity N A PORT E Auto Model Refer to DVD R W model number Device type Unknown device Capacity N A PORT F Auto Model Hard disk drive Model No Drive Type Hard drive Capacity 500GB 78 Chapter 5 Servicing ...

Page 79: ...ot option Enable Disable 1 Hard drive C 2 Embedded SATA Port Optical Drive E 3 Embedded NIC Port 1 Partition 1 Partition 1 BRCM MBA Slot 0100 V15 2 10 Hard disk drive sequence RAID Controller in Slot 6 NA One time boot Column 1 heading Column 2 heading One time Boot Device List Disabled BIOS Boot Sequence Device Hard drive C BIOS Hard Disk Drive Sequence Device RAID Controller UFFI Boot Sequence D...

Page 80: ...SB Port On Embedded NIC1 and NIC2 Enabled OS Watchdog Timer Disabled I O AT DMA Engine Disabled Embedded Video Controller Enabled SR 10V Globe Engine Disabled Memory mapped I O above 4GB settings Disabled Slot Displacement Slot 1 to Slot 6 Enabled 80 Chapter 5 Servicing ...

Page 81: ...ate 115200 Remote Terminal Type VT100 VT220 Redirection After Boot Enabled System Profile Performance CPU Power Management Maximum Performance Memory Frequency Maximum Performance C1E Enabled C States Enabled Monitor Mwait Enabled Memory Partrol Scrub Standard Memory refresh rate 1x Memory Operating Voltage Auto Collaborative CPU Performance Control Disabled System profile settings System profile ...

Page 82: ...atus Unlocked TPM Security Off TPM Activation No Change TPM Clear No Intel TXT Off Power Button Enabled NMI Button Disable AC Power Recovery Off Miscellaneous settings System Time System date Asset Tag Keyboard Num Lock On Report Keyboard Errors Report F1 F2 Prompt on Error Enabled 82 Chapter 5 Servicing ...

Page 83: ...Auto Negotiation On Network Speed 100 Mbps Duplex Mode Full Duplex 5 9 6 BIOS settings for Tab 51155517 500 System information Product name Dell PowerEdge T320 server System model name T320 001 BIOS Version 2 0 22 or later System manufacturer Dell System Manufacturer Contact info www dell com System CPLD version 100 or later 83 ...

Page 84: ...vanced ECC Mode Node interleaving Disabled CPU information Alternate RTID Disabled Virtualization technology Enabled Adjacent cache line prefetcher Enabled Hardware prefetcher Enabled DCU Steamer Prefetcher Enabled DCU IP Prefetcher Enabled Execute Disable Enabled Logical Processor Idling Disabled Number of Cores per processor All Processor 64 bit Support Yes Processor Core Speed 1 80 GHz 84 Chapt...

Page 85: ... ATA Mode or AHCI Mode ATTENTION During the Init Media installation if the installation is unresponsive change the ATA Drive setting from ATA Mode to AHCI Mode PORT A B C D Auto Model Unknown Device type Unknown device Capacity N A PORT E Auto Model Refer to DVD R W model number Device type Unknown device Capacity N A Boot settings Boot Mode BIOS Boot Sequence Retry Disabled Boot sequence 85 ...

Page 86: ... One time boot Column 1 heading Column 2 heading One time Boot Device List Disabled BIOS Boot Sequence Device Hard drive C BIOS Hard Disk Drive Sequence Device RAID Controller UFFI Boot Sequence Device Embedded NIC Integrated devices User Accessible USB Ports All Ports On Internal USB Port On Embedded NIC1 and NIC2 Enabled OS Watchdog Timer Disabled I O AT DMA Engine Disabled Embedded Video Contro...

Page 87: ...erial Device 1 Fail Safe Baud Rate 115200 Remote Terminal Type VT100 VT220 Redirection After Boot Enabled System profile settings System profile Performance System security Intel AES NI Enabled System Password Setup Password Password Status Unlocked TPM Security Off TPM Activation No Change TPM Clear No Intel TXT Off Power Button Enabled NMI Button Disable AC Power Recovery Last 87 ...

Page 88: ...1 Failover Network None MAC Address XXXXXXXXXXXX Auto Negotiation On Network Speed 100 Mbps Duplex Mode Full Duplex 5 9 7 BIOS settings for Tab 51155517 600 System information Product name Dell PowerEdge T320 server System model name T320 001 BIOS Version 2 0 22 or later System manufacturer Dell System Manufacturer Contact info www dell com System CPLD version 100 or later 88 Chapter 5 Servicing ...

Page 89: ...ng mode Advanced ECC Mode Node interleaving Disabled CPU information Logical processor Enabled Alternate RTID Disabled Virtualization technology Enabled Adjacent cache prefetcher Enabled Hardware prefetcher Enabled DCU Steamer Prefetcher Enabled DCU IP Prefetcher Enabled Execute Disable Enabled Logical Processor Idling Disabled Number of Cores per processor All Processor 64 bit Support Yes Process...

Page 90: ...I Mode ATTENTION During the Init Media installation if the installation is unresponsive change the ATA Drive setting from ATA Mode to AHCI Mode PORT A B C D Auto Model Unknown Device type Unknown device Capacity N A PORT E Auto Model DVD R W model number Device type Unknown device Capacity N A Boot settings Boot Mode BIOS Boot Sequence Retry Disabled Boot sequence 90 Chapter 5 Servicing ...

Page 91: ...sequence RAID Controller in Slot 6 PERC H710 Adapter One time boot Column 1 heading Column 2 heading One time Boot Device List Disabled BIOS Boot Sequence Device Hard drive C BIOS Hard Disk Drive Sequence Device RAID Controller UFFI Boot Sequence Device Embedded NIC Integrated devices User Accessible USB Ports All Ports On Internal USB Port On Embedded NIC1 and NIC2 Enabled OS Watchdog Timer Disab...

Page 92: ...erial Connector Serial Device 1 Fail Safe Baud Rate 115200 Remote Terminal Type VT100 VT220 Redirection After Boot Enabled System profile settings System profile Performance CPU Power Management Maximum Performance Memory Frequency Maximum Performance C1E Enabled C States Enabled Monitor Mwait Enabled Memory Partrol Scrub Standard Memory refresh rate 1x Memory Operating Voltage Auto Collaborative ...

Page 93: ...ange TPM Status Unknown TPM Clear No Intel TXT Off Power Button Enabled NMI Button Disable AC Power Recovery Off AC Power Recovery Delay Immediate User defined delay 60s to 240s 60 Miscellaneous settings System Time HH MM SS System date DD MM YYYY Asset Tag Keyboard Num Lock On Report Keyboard Errors Report F1 F2 Prompt on Error Enabled In System Characterization Enabled 93 ...

Page 94: ...s 5 10 Spare parts Item Description Dell part number Honeywell part number Processor Intel Xeon E5 2430 2 20 GHz 7 2GT s Intel QPI 319 1186 51155517 901 Intel Xeon E5 2403 1 80 GHz 10M Cache 6 4GT s QPI No Turbo 4C 80 W 319 0183 51155517 902 Expansion Ram 2 GB RDIMM 1333 MHz or faster 317 5938 51155148 909 Keyboard Dell QWERTY Keyboard 331 2254 51155517 903 Mouse Optical Mouse Two Buttons USB Blac...

Page 95: ... 342 4047 51155517 908 PERC H710 Integrated RAID Controller 512 MB NV Cache 342 3529 51155517 909 SMPS Dell Single Cabled Power Supply 350 W 331 7022 51155517 910 Dell Hot Plug Power Supply 495 W 331 4603 51155517 911 DVD Drive DVD RW SATA Internal 318 1391 51155517 912 5 11 Troubleshooting 5 11 1 Integrated Dell Remote Access Controller 6 iDRAC6 issue Refer to the PN2014 13 for further informatio...

Page 96: ...f any may be found in the materials accompanying the product in the documents or files accompanying such third party materials in a file named third_ party_licenses on the media containing the product or at http www honeywell com ps thirdpartylicenses Documentation feedback You can find the most up to date documents on the Honeywell Process Solutions support website at http www honeywellprocess co...

Page 97: ...te https www honeywellprocess com en US contact us customer support contacts Pages default aspx Training classes Honeywell holds technical training classes that are taught by process control systems experts For more information about these classes contact your Honeywell representative or see http www automationcollege com 97 ...