8-10 System Upgrade
Replacing 3.5-inch Hard Disk Drive
Follow the procedure below to remove the failed hard disk. If the hard disk fails, it should be replaced
with new device with the server powered-on.
IMPORTANT:
Make sure to read “ANTI-STATIC MEASURES” and “PREPARING YOUR SYSTEM FOR
UPGRDE.” You can replace disks during continuous operation.
Replacing the Hard Disk Drive
1.
Locate the failed hard disk.
When a hard disk fails, the DISK ACCESS LED on the hard disk drive’s handle illuminates
amber.
2.
Remove the failed hard disk referring to “Replacing Failed Hard Disk Drives” on page 3-21 and
“Removing 3.5-inch Hard Disk Drive” on page 8-9.
No need to shut down Windows Server 2003.
3.
Refer to the steps in “Installing 3.5-inch Hard Disk Drive” to install a new hard disk.
CHECK:
The hard disk to be installed for replacement must have the same specifications as its
mirroring hard disk.
After disk physical format, refer to “Disk Operation” in Chapter 3 and restore the dual
configuration. For physical format, see “SAS BIOS Adaptec SAS/SATA Configuration
Utility” in Chapter 4, “System Configuration,” and format disks with Disk Utilities. To
format disks, select “Server,” “Monitoring Configuration” and set “Option ROM Scan
Monitoring” to Disabled.” For how to configure the setting, see “System BIOS SETUP ”
in Chapter 4, “System Configuration.”
4.
Restore the redundant configuration (see Chapter 3).
Summary of Contents for Express5800/320Fd-MR
Page 13: ...v Appendix B I O Port Addresses This appendix lists factory assigned I O port addresses...
Page 19: ...xi THIS PAGE IS INTENTIONALLY LEFT BLANK...
Page 43: ...2 10 General Description Rear View...
Page 47: ...2 14 General Description CPU IO Module CPU IO module...
Page 67: ...2 34 General Description This page is intentionally left blank...
Page 79: ...3 12 Windows Setup and Operation 3 Confirm that RDR of the disk is cancelled...
Page 106: ...Windows Setup and Operation 3 39 This page is intentionally left blank...
Page 198: ...4 92 System Configuration This page is intentionally left blank...
Page 370: ......
Page 371: ...This page is intentionally left blank...
Page 389: ...6 18 Maintenance 3 Stop of PCI module 1 4 Start of PCI module 1...
Page 391: ...6 20 Maintenance This page is intentionally left blank...
Page 465: ...System Upgrade 8 31 board must not be mixed with N8804 005 or N8803 035...
Page 480: ......
Page 483: ......