5-168 Installing and Using Utilities
Verifying If RDR Disks Are Resynchronizing
When you complete or abort the Active Upgrade process, the system reestablishes the mirrors
between the RDR partner disks in each CPU- I
⁄
O enclosure. If you intend to initiate another
upgrade process, you must wait for the resynchronization to complete before you do so.
You can tell if a disk is resynching by viewing the LEDs on the front panel of the disk. For
information about interpreting the LEDs, see “Disk Operations Using the RDR (Rapid Disk Resync)
Function” in Chapter 3, “Windows Setup and Operation.”
You can also view the status of your disks using one of the following methods:
•
Run a readiness check. On the Active Upgrade page, click Retry. If the disks are still
resynching, the upgrade state will be reported as
Fault Tolerant\Idle\Broken
and the activity
log will display errors indicating that the disks are not ready.
•
Verify the disks on the Disk Selection page. Any volume that is in red is simplexed (and thus,
probably still resynching). When a disk volume is only green, it is duplxed and you can start
another upgrade.
For more about the disk status on the
Disk Selection page
, see “Selecting Disks to Upgrade”
on 5-116.
To view the status of an RDR virtual disk in RDR Utility
1.
On RDR Utility, click
Logical Disk Information
.
2.
Click one of the
RDR Virtual Disk
items (RDR Virtual Disk x).
3.
Check the value of the
Status
property, which displays
Resync nn% (
where
nn
is the
percentage completed) while the disk is resynchronizing. When the resync process is finished,
the value is
None
.
Ensure that the value of the
Status
property for all RDR Virtual Disks is
None
before you retry the
Active Upgrade process.
TIPS:
Selecting Disks to Upgrade, page 5-116
Performing a Readiness Check, page 5-132
Viewing Active Upgrade Process Status, page 5-158
Troubleshooting, page 5-164
Summary of Contents for Express5800/320Fd-MR
Page 13: ...v Appendix B I O Port Addresses This appendix lists factory assigned I O port addresses...
Page 19: ...xi THIS PAGE IS INTENTIONALLY LEFT BLANK...
Page 43: ...2 10 General Description Rear View...
Page 47: ...2 14 General Description CPU IO Module CPU IO module...
Page 67: ...2 34 General Description This page is intentionally left blank...
Page 79: ...3 12 Windows Setup and Operation 3 Confirm that RDR of the disk is cancelled...
Page 106: ...Windows Setup and Operation 3 39 This page is intentionally left blank...
Page 198: ...4 92 System Configuration This page is intentionally left blank...
Page 370: ......
Page 371: ...This page is intentionally left blank...
Page 389: ...6 18 Maintenance 3 Stop of PCI module 1 4 Start of PCI module 1...
Page 391: ...6 20 Maintenance This page is intentionally left blank...
Page 465: ...System Upgrade 8 31 board must not be mixed with N8804 005 or N8803 035...
Page 480: ......
Page 483: ......