7-24 Troubleshooting
Event Log
"The NMS Service terminated unexpectedly." is recorded in the system event log:
→
Although the following log may be recorded in the system event log when starting
the system, or after exchanging PCI modules, there is no real problem on
operation. Change of a setup with PROSet II will become invalid if NMS service
stops, but you can change a setup normally because NMS service will be
automatically started when PROSet II is started.
“Source:
Service Control Manager
Event ID:
7031
Description: The NMS service terminated unexpectedly. This has occurred 1
time(s). The following corrective action will be taken in 0
milliseconds: No action.”
iANSMiniport-related logs are recorded in the system event log:
→
The logs of the source “iANSMiniport” are the logs about the duplex of the
network. The following logs may be recorded in the system event log after starting
the system or after setting duplex, but there is no problem on operation.
Source:
iANSMiniport
Type:
Warning
Event ID:
35
Description: Initializing “Virtual Team Adaptor” that lack adapter “Number of
missed adaptors.” Check if all adapters exist and function properly.
Source:
iANSMiniport
Type:
Warning
Event ID:
13
Description: “Physical Adaptor” is invalid in the team.
Source:
iANSMiniport
Type:
Warning
Event ID:
11
Description: The following adapter link is not connected: “Physical Adaptor.”
Source:
iANSMiniport
Type:
Error
Event ID:
16
Description: “Virtual Team Adaptor”: the last adapter lost the link.
The team network lost the connection.
Source:
iANSMiniport
Type:
Warning
Event ID:
22
Description: The primary adapter did not detect the following probe: “Physical
Adaptor.” Reason: The team may be divided.
Summary of Contents for Express5800/320Fd-MR
Page 13: ...v Appendix B I O Port Addresses This appendix lists factory assigned I O port addresses...
Page 19: ...xi THIS PAGE IS INTENTIONALLY LEFT BLANK...
Page 43: ...2 10 General Description Rear View...
Page 47: ...2 14 General Description CPU IO Module CPU IO module...
Page 67: ...2 34 General Description This page is intentionally left blank...
Page 79: ...3 12 Windows Setup and Operation 3 Confirm that RDR of the disk is cancelled...
Page 106: ...Windows Setup and Operation 3 39 This page is intentionally left blank...
Page 198: ...4 92 System Configuration This page is intentionally left blank...
Page 370: ......
Page 371: ...This page is intentionally left blank...
Page 389: ...6 18 Maintenance 3 Stop of PCI module 1 4 Start of PCI module 1...
Page 391: ...6 20 Maintenance This page is intentionally left blank...
Page 465: ...System Upgrade 8 31 board must not be mixed with N8804 005 or N8803 035...
Page 480: ......
Page 483: ......