Troubleshooting 7-25
The log above gets output in the process of system start up or dual mode setting.
When the log is recorded, there is no problem to the system by the above warning
if the status of the adapter in the team is “Active” or “Standby.” For the status of
the adapter, check in properties of the team adapter from the device manager.
ESMCommonService related log is recorded in the system event log:
→
Following event log is recorded while the system operation in some cases. The log
indicates detection of an event that is not critical event for the server operation,
and the event is amendable. This doesn’t affect the system as long as the event
never occurs repeatedly.
Source:
ESMCommonService
Type:
Warning
Event ID:
1309
Description: ECC 1 bit error occurred on the system bus.
EvntAgnt log is recorded in the application event log:
→
This event does not have any influence to the system not to SNMP services. Thus
no measurement is required.
Source: EvntAgnt
Event ID:
1003
Description: TraceFileName parameter not located in registry; Default trace file
used is .
Source: EvntAgnt
ID: 1015
Description: TraceLevel parameter not located in registry; Default trace level
used is 32.
SCSI control error appears in the system event log:
→
This symptom occurs, for example, when a SCSI chip receives a reset request
from a different SCSI chip. The process will be continued properly by the retry
function.
It is likely to occur when the server shifts from the simplex mode to the duplex
mode at OS startup or during maintenance operations. If the number of the
following errors recorded in the system event log is few, ignore the errors.
This error is logged about 5 to 50 times in two or three minutes when the server
shifts from the simplex mode to the duplex mode during maintenance operations.
Ignore these errors as well.
Source: adpu320
Type: Error
Event ID:
11
Description: The driver detected a controller error on \Device\Scsi\adpu320xx.
If this error is recorded many times, the hard disk drive may be faulty. Contact
your service representative.
Summary of Contents for Express5800/320Fd-MR
Page 13: ...v Appendix B I O Port Addresses This appendix lists factory assigned I O port addresses...
Page 19: ...xi THIS PAGE IS INTENTIONALLY LEFT BLANK...
Page 43: ...2 10 General Description Rear View...
Page 47: ...2 14 General Description CPU IO Module CPU IO module...
Page 67: ...2 34 General Description This page is intentionally left blank...
Page 79: ...3 12 Windows Setup and Operation 3 Confirm that RDR of the disk is cancelled...
Page 106: ...Windows Setup and Operation 3 39 This page is intentionally left blank...
Page 198: ...4 92 System Configuration This page is intentionally left blank...
Page 370: ......
Page 371: ...This page is intentionally left blank...
Page 389: ...6 18 Maintenance 3 Stop of PCI module 1 4 Start of PCI module 1...
Page 391: ...6 20 Maintenance This page is intentionally left blank...
Page 465: ...System Upgrade 8 31 board must not be mixed with N8804 005 or N8803 035...
Page 480: ......
Page 483: ......