3-20 Windows Setup and Operation
Replacing Failed Hard Disk Drives
The following describes how to locate and replace the failed hard disk. The failed hard disk
should be replaced with the server powered on.
How to Locate Failed Disks
1.
From [Start], select [All Programs], [RDR] and click [RDR Utility] to start RDR Utility.
2.
From the tree on the left pane of [RDR Utility], select each disk and check the values of
[MTBF: Current] and [MTBF:NumberOfFaults] in the right pane.
TIPS:
For RDR Utility, see “About RDR Utility” on page 3-4.
[Description of each MTBF value]
Property name
Description
Normal value*
MTBF: HardCurrent
Mean time between hardware failures.
Unknown
MTBF: SoftCurrent
Mean time between software failures.
Unknown
* The normal value denotes the value of when no error has occurred.
If either of the values is different from the normal value, the disk has an error.
Procedures to Replace Failed Disks
This section describes a procedure for replacing a disk when a failure occurs to a disk that is
duplicated by the RDR function.
IMPORTANT:
The display of RDR Utility is not updated automatically. Therefore, update it every time you
check the status of disks by clicking [Refresh] from [Action] on the menu or pressing
F5.
Do not
update RDR Utility frequently immediately after inserting a disk.
Here, an example that a failure of the disk in slot 2 of the PCI module 0 is determined as described
in “How to Locate Failed Disks” is explained.
1.
From [Start], click [All Programs], point to [RDR], and select [RDR Utility] to start RDR
Utility.
2.
Remove the disk in the slot 2 of the PCI module 0.
3.
Insert a new disk to the slot 2 of the PCI module 0.
RDR is automatically set to the inserted disk and synchronization starts.
Summary of Contents for Express5800/320Fd-MR
Page 13: ...v Appendix B I O Port Addresses This appendix lists factory assigned I O port addresses...
Page 19: ...xi THIS PAGE IS INTENTIONALLY LEFT BLANK...
Page 43: ...2 10 General Description Rear View...
Page 47: ...2 14 General Description CPU IO Module CPU IO module...
Page 67: ...2 34 General Description This page is intentionally left blank...
Page 79: ...3 12 Windows Setup and Operation 3 Confirm that RDR of the disk is cancelled...
Page 106: ...Windows Setup and Operation 3 39 This page is intentionally left blank...
Page 198: ...4 92 System Configuration This page is intentionally left blank...
Page 370: ......
Page 371: ...This page is intentionally left blank...
Page 389: ...6 18 Maintenance 3 Stop of PCI module 1 4 Start of PCI module 1...
Page 391: ...6 20 Maintenance This page is intentionally left blank...
Page 465: ...System Upgrade 8 31 board must not be mixed with N8804 005 or N8803 035...
Page 480: ......
Page 483: ......