Installing and Using Utilities 5-27
LAN Monitoring Report
The LAN monitoring function defines the line status depending on the number of transmission
packets and the number of packet errors within a certain period. Thus, the LAN monitoring function
may report a line fault or high line load only in a temporary high line impedance state. If a normal
state recovery is reported immediately, temporal high line impedance may have occurred thus there
is not any problem.
LAN Monitoring Threshold
Because the NEC Express5800/ft series detects hardware faults on the network in the driver level,
NEC ESMPRO Agent does not monitor line faults. Thus, the value set for “Line fault occurrence
rate” of a [LAN] tab of [NEC ESMPRO Agent properties] in the control panel is not used.
Community Authority
Depending on your OS type or its version, settings for community, SNMP service’s security
function, are not made, or default settings of authority are different.
To enable the remote shutdown and threshold change functions via NEC ESMPRO Manager, make
settings of community and set its authority to “READ CREATE” or “READ WRITE.”
Hardware Monitoring by ESMPRO
In NEC Express5800/320Fc-MR, an alert report is not issued if an error on temperature/fan/power
supply/voltage is detected in CPU module and PCI module.
Moreover, the trees [Temperature], [Fan], [Voltage], and [Power Supply] are not displayed on
[System Environment] of DataViewer of NEC ESMPRO Manager.
System Environment Monitoring
On NEC Express5800/320Fd-MR, monitoring of temperature, fan and voltage under [System
Environment] of [ESMPRO] tree in the DataViewer is set to enable and cannot be changed to
disable by default.
Change of SNMP Community
If the security setting of the SNMP Service of a system, where the NEC ESMPRO Agent is installed,
is changed from the default “public” to a community name, change the community settings of the
NEC ESMPRO Agent, too.
1.
Double-click the [NEC ESMPRO Agent] icon in [Control Panel].
2.
Select a desired community name from the [SNMP Community] list box in [SNMP
Summary of Contents for Express5800/320Fd-MR
Page 13: ...v Appendix B I O Port Addresses This appendix lists factory assigned I O port addresses...
Page 19: ...xi THIS PAGE IS INTENTIONALLY LEFT BLANK...
Page 43: ...2 10 General Description Rear View...
Page 47: ...2 14 General Description CPU IO Module CPU IO module...
Page 67: ...2 34 General Description This page is intentionally left blank...
Page 79: ...3 12 Windows Setup and Operation 3 Confirm that RDR of the disk is cancelled...
Page 106: ...Windows Setup and Operation 3 39 This page is intentionally left blank...
Page 198: ...4 92 System Configuration This page is intentionally left blank...
Page 370: ......
Page 371: ...This page is intentionally left blank...
Page 389: ...6 18 Maintenance 3 Stop of PCI module 1 4 Start of PCI module 1...
Page 391: ...6 20 Maintenance This page is intentionally left blank...
Page 465: ...System Upgrade 8 31 board must not be mixed with N8804 005 or N8803 035...
Page 480: ......
Page 483: ......