8-20 System Upgrade
7.
Remove the DIMM connector cover from
the socket in which the DIMM is installed.
A DIMM connector cover is installed to
the open socket. When the levers on both
ends of the connector are opened, the
DIMM connector cover is unlocked and
you can remove the cover.
IMPORTANT:
Keep the removed DIMM connector
cover.
8.
Insert a DIMM into the DIMM socket vertically.
TIPS:
Pay attention to the orientation of the
DIMM. The terminal of the DIMM has a
cutout to prevent misinsertion.
After the DIMM is completely inserted into
the socket, the levers are automatically closed.
9.
Attach the memory duct
10.
Place the top cover of the CPU/IO module and
secure it with the screws.
11.
Refer to page 8-15 and install the CPU/IO module.
12.
Connect the power cords.
13.
Press the POWER switch to power on the server.
14.
Verify that POST displays no error message.
If POST displays an error message, write it down and see the POST error message list on page
7-4.
DIMM connector
Summary of Contents for Express5800/320Fd-MR
Page 13: ...v Appendix B I O Port Addresses This appendix lists factory assigned I O port addresses...
Page 19: ...xi THIS PAGE IS INTENTIONALLY LEFT BLANK...
Page 43: ...2 10 General Description Rear View...
Page 47: ...2 14 General Description CPU IO Module CPU IO module...
Page 67: ...2 34 General Description This page is intentionally left blank...
Page 79: ...3 12 Windows Setup and Operation 3 Confirm that RDR of the disk is cancelled...
Page 106: ...Windows Setup and Operation 3 39 This page is intentionally left blank...
Page 198: ...4 92 System Configuration This page is intentionally left blank...
Page 370: ......
Page 371: ...This page is intentionally left blank...
Page 389: ...6 18 Maintenance 3 Stop of PCI module 1 4 Start of PCI module 1...
Page 391: ...6 20 Maintenance This page is intentionally left blank...
Page 465: ...System Upgrade 8 31 board must not be mixed with N8804 005 or N8803 035...
Page 480: ......
Page 483: ......