5-72 Installing and Using Utilities
Dump Collection
To collect the dump file with NEC ESMPRO Manager, use [CPU Module]
→
[Maintenance] tree in
the DataViewer.
To collect the dump with the ft server utility, use the utility screen of the component.
IMPORTANT:
Acquire the dump only for the examination of a fault.
The dump can be collected in two ways. In each way, the dump file is collected with the same path
and file name “%SystemDrive%\NECDump\MEMORY.DMP” as the dump file of the OS standard.
Collecting dump of inactive module
The dump is acquired from the inactive CPU module (due to the occurrence of a fault or
forced stop).
Collecting dump under system operation
Either of the CPU modules is entered into the offline state and the dump is collected
during system operation. After the acquisition, the CPU module is returned to the online
state again. This can be done only in the duplex system.
The table below shows the potential cases in which the dump is acquired.
Saving dump of stopped module
Saving dump of component
under system operation
Component
Remote
Local Remote
Local
CPU Module
–
When a fault or malfunction
occurs in the system.
Save the dump if requested
by maintenance personnel.
Executable in the following
module state:
•
The amber LED is on
However, this function
operates only in a fault
state. An execution error
occurs in any other cases.
The amber LED is on when
the module is in one of the
following states:
•
Removed
•
Broken
•
Shot
•
Firmware
Completion of update
•
No fault found by
diagnosis
When a fault or
malfunction occurs
in the system.
Save the dump if
requested by
maintenance
personnel.
Executable in the
following module
state (this can be
viewed on manager
screen):
•
Duplex
When a fault or
malfunction occurs in
the system.
Save the dump if
requested by
maintenance
personnel
Executable in the
following module
state:
•
When only the
green LED is on and
the module is in
redundant
configuration state
Only the green LED is
on when the module is
in the following state:
•
Duplex
Remote: Executable from remote management PC by using NEC ESMPRO Manager
Local:
Executable on local server by using ft server utility
–: Not
support
Summary of Contents for Express5800/320Fd-MR
Page 13: ...v Appendix B I O Port Addresses This appendix lists factory assigned I O port addresses...
Page 19: ...xi THIS PAGE IS INTENTIONALLY LEFT BLANK...
Page 43: ...2 10 General Description Rear View...
Page 47: ...2 14 General Description CPU IO Module CPU IO module...
Page 67: ...2 34 General Description This page is intentionally left blank...
Page 79: ...3 12 Windows Setup and Operation 3 Confirm that RDR of the disk is cancelled...
Page 106: ...Windows Setup and Operation 3 39 This page is intentionally left blank...
Page 198: ...4 92 System Configuration This page is intentionally left blank...
Page 370: ......
Page 371: ...This page is intentionally left blank...
Page 389: ...6 18 Maintenance 3 Stop of PCI module 1 4 Start of PCI module 1...
Page 391: ...6 20 Maintenance This page is intentionally left blank...
Page 465: ...System Upgrade 8 31 board must not be mixed with N8804 005 or N8803 035...
Page 480: ......
Page 483: ......