NPort P5250A Series Quick 

Installation Guide 

First Edition, August 2011 

Overview 

NPort P5250A series device servers are compact, palm-sized data 
communication devices that allow you to control RS-232/422/485 
serial devices over a TCP/IP-based Ethernet. 

Note: 

“-T” indicates an extended temperature model. 

Package Checklist   

Before installing the NPort P5250A series device server, verify that 
the package contains the following items: 

 

1 NPort P5250A serial device server   

 

4 stick-on pads   

 

Document & Software CD   

 

Quick Installation Guide   

 

Product Warranty Statement   

Optional Accessory 

 

DK-35A: DIN-Rail Mounting Kit (35 mm)   

Notify your sales representative if any of the above items are 
missing or damaged. 

Hardware Introduction 

As shown in the following figures, NPort P5250A series device 
servers have one male DB9 port for transmitting RS-232/422/485 
serial data. 

 

 

 

 

 

 

 

 

Reset Button

Press and hold the Reset button for 5 seconds to 

load factory defaults

: Use a pointed object, such as a straightened 

paper clip or toothpick, to depress the reset button. This will cause 
the Ready LED to blink on and off. Once the Ready LED stops 
blinking (after about 5 seconds), release the reset button and the 
device server will start to load the factory defaults. 

 

WARNING 

1. The equipment is designed for in-building 
installation only and is not intended to be connected 
to exposed (outside plant) networks. 
2. This equipment is intended to be used in a 
Restricted Access Location. 
3. This product is intended to be supplied by an 
UL60950-1 and IEC60950-1 certified Power Unit 
marked “LPS” and rated output rating: 12 to 48 VDC, 
0.18 A minimum, 75°C.

 

 

 

 
 

LED Indicators

—NPort P5250A’s top panel has three LED 

indicators, which are described in the following table. 

LED 
Name 

LED 
Color 

LED Function 

Ready 

Red 

Steady on: Power is on and the NPort is booting 

up. 

Blinking:  Indicates an IP conflict, or DHCP or 

BOOTP server is not responding 
properly. 

Green 

Steady on: Power is on and the NPort is 

functioning normally. 

Blinking:  The NPort has been located by the 

NPort Administrator’s Location 
function. 

Off  Power is off, or a power error.. 

Link 

Orange  10 Mbps Ethernet connection. 

Green  100 Mbps Ethernet connection. 

Off  Ethernet cable is disconnected. 

Tx/Rx  Orange  Serial port is receiving data. 

Green  Serial port is transmitting data. 

Off 

No data is being transmitted or received through 
the serial port. 

Adjustable pull high/low resistor and terminator for RS-485 

 

Remove the NPort P5250A’s top cover 
and you will find DIP switches to adjust 
each serial port’s pull-high, pull-low, 
and terminator. 

Do not use the 1 KΩ 

setting with RS-232 mode, as doing so 
will degrade the RS-232 signals and 
shorten the communications range.

 

 

SW 

Pull-high resistor  Pull-low resistor 

Terminator 

ON 

1 K

Ω

 

1 K

Ω

 

120

Ω

 

OFF 

*150 K

Ω

 

*150 K

Ω

 

*--- 

*Default 

 

 