background image

INSTALLATION INSTRUCTIONS

95-7711

Q7055B1047

Open View Net Server (OVN)

WARNING

This equipment generates, uses and can radiate 
radio frequency energy, and if not installed and 
used in accordance with the Instructions Manual, 
may cause interference with radio communication. 
It has been tested and found to comply with the 
limits for a Class A computing device pursuant to 
Subpart J of Part 15 or FCC Rules, which are 
designed to provide reasonable protection against 
such interference when operated in a commercial 
environment. Operation of this equipment in a 
residential area is likely to cause interference, in 
which case, users at their own expense will be 
required to take whatever measures may be 
required to correct the interference. Any 
unauthorized modification of this equipment may 
result in the revocation of the owner's authority to 
continue its operation.

The Q7055B1047 Open View Net Server (OVN) is a 
Web-enabled operator interface that facilitates secure and 
easy access to a Honeywell Building Management System 
(BMS) through the Internet. It provides a connection of a 
Honeywell XL5000 controller communication bus to an 
industry standard TCP/IP Ethernet LAN/WAN, delivering 
exceptional price/performance to meet the requirements of 
both building owners and service providers.

With its combination of scalable performance, density and low 
per - port pricing, the OVN allows network-layer capabilities to 
be extended to a much wider range of network configurations 
and environments. OVN supports a full range of Building 
Management System (BMS) features such as commanding of 
points as well as performing complex functions like alarm and 
schedule management. Advanced features like graphics, 
trends and reports give enhanced flexibility and total control 
when accessing the Building Management System from a 
remote location. Customers can now gain the advantages of 
high-performance network and services, including traffic 
management, to more locations throughout the network.

This INSTALLATION INSTRUCTIONS document covers the 
following OVN server:
— Q7055B1047. Provides a single RS-485 DC coupled 

C-Bus compatible communication channel for as many as 
five Excel 5000™ family devices with up to 76.8 kbps and 
single RS-232 and 10/100BaseT interfaces.

Additionally, each OVN is equipped with a RJ-45 
10/100BaseT connector, plus an RS-232 interface. 
(See Fig. 1).

Fig. 1. OVN network.

The Q7055B1047 OVN Server is used in systems for signaling 
in energy management systems (UL 916). In addition, the 
following standards apply: requirements of Canadian province 
and local building codes; CEC 22.1 Canadian Code.

INTERNET

BROWSER

EBI

OVN

SINGLE C-BUS 

(ONLY FOR XL5000

 CONTROLLERS 

FAMILY)

EBI

WORKSTATION

M25198

OVN

SINGLE C-BUS 

(ONLY FOR XL5000

 CONTROLLERS 

FAMILY)

TCP/IP

Summary of Contents for Q7055B1047

Page 1: ...ice providers With its combination of scalable performance density and low per port pricing the OVN allows network layer capabilities to be extended to a much wider range of network configurations and environments OVN supports a full range of Building Management System BMS features such as commanding of points as well as performing complex functions like alarm and schedule management Advanced feat...

Page 2: ...0013930 001 Mounting Bracket BEFORE INSTALLATION Perform the following steps prior to installing the OVN server 1 Verify that the product has been received without damage 2 Verify that the correct OVN server has been delivered 3 Check the package contents The following items are included in each product package Building Network Adapter device Building Network Adapter driver software CD Building Ne...

Page 3: ...own on the desk Remove the four feet from the bottom of the OVN by pushing horizontally away from the housing with a flat screwdriver Push the four inserts included fully and horizontally into the housing Adjust the four retaining clips included on top of the inserts Fasten the retaining clips with the included four screws Use the housing with the clips to mark the positions of the four mounting h...

Page 4: ...EPARATED FROM ALL NON POWER LIMITED WIRING BY A MINIMUM DISTANCE OF 1 4 IN 6 MM NOTE TYPICAL MOUNTING LOCATIONS FOR 14005680 089582 592 FIBER OPTIC INTERFACE 1 ALL WIRING MUST BE IN ACCORDANCE WITH NFPA 70 NATIONAL ELECTRICAL CODE AND ALL APPLICABLE LOCAL CODES 2 G GROUNDING CONDUCTOR 3 GROUND CONNECTION 8 32 STUD WITH 8 32 KEPS NUT 4 GROUND CONNECTION FOR 14507678 SERIES PNET PROTECTOR AND OTHER ...

Page 5: ... at the end of the cable 2 Strip the two power cable ends and insert each cable end into the openings of the 3 pole Phoenix connectors that are marked for power 3 Fasten them with a screwdriver 4 Connect a chassis ground to the third position on this connector as marked NOTE The polarity of the 3 pole Phoenix power connector for DC power supplies is don t care Field Bus Connection The 2 pole Phoen...

Page 6: ...AN via an Ethernet Hub the required cable should be configured as shown in Fig 8 Fig 8 Straight through pinning for OVN to Ethernet Hub connections Connect OVN to Workstation When an OVN needs a direct connection to a workstation without using an Ethernet Hub a crossover cable is required Fig 9 shows how the different signals should be connected Fig 9 Crossover pinning for OVN to workstation direc...

Page 7: ...g at 100 mbps ACTIVITY Link activity indicator Green will blink if there is any activity transmission reception on the LAN 6 AC DC IN 24 V Power connector for 24 Vac 50 Hz to 60Hz or 24 Vdc power supplies and chassis ground Power consumption is 8 VA connected via 10 100BaseT cable An external power supply is required 7 10 100BASET 10 100BaseT RJ 45 Ethernet LAN connector meets the requirements of ...

Page 8: ... Honeywell International Inc Honeywell Limited Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley MN 55422 Scarborough Ontario M1V 4Z9 www honeywell com buildingsolutions U S Registered Trademark 2006 Honeywell International Inc 95 7711 J I 04 06 ...