12 DATA USED FOR POSITIONING CONTROL
12.5 Block Start Data
[Da.14] Parameter
Set the value as required for "[Da.13] Special start instruction".
[Da.13] Special start
instruction
Setting
value
Setting details
Block start (Normal start)
Not used. (There is no need to set.)
Condition start
1 to 10
Set the condition data No. (Data No. of "condition data" is set up for the condition judgment.) (Refer to
Page 463 Condition Data for details on the condition data.)
Wait start
Simultaneous start
Repeated start (FOR loop)
0 to 255
Set the number of repetitions.
Repeated start (FOR condition)
1 to 10
Set the condition data No. (Data No. of "condition data" is set up for the condition judgment.)