384
12 DATA USED FOR POSITIONING CONTROL
12.1 Types of Data
■
Monitoring the state
Monitor details
Corresponding item
Monitor the latest error code that occurred with the axis
[Md.23] Axis error No.
Monitor the latest warning code that occurred with the axis
[Md.24] Axis warning No.
Monitor the valid M codes
[Md.25] Valid M code
Monitor the axis operation state
[Md.26] Axis operation status
Monitor the movement amount after the current position control switching when using "speed-position
switching control".
[Md.29] Speed-position switching control
positioning movement amount
Monitor the external input/output signal and flag
[Md.30] External input signal
[Md.31] Status
Monitor the movement amount from near-point dog ON to machine home position return completion.
[Md.34] Movement amount after near-point
dog ON
Monitor the current torque limit value
[Md.35] Torque limit stored value/forward
torque limit stored value
[Md.120] Reverse torque limit stored value
Monitor the "instruction code" of the special start data when using special start
[Md.36] Special start data instruction code
setting value
Monitor the "instruction parameter" of the special start data when using special start
[Md.37] Special start data instruction
parameter setting value
Monitor the "start data No." of the special start data when using special start
[Md.38] Start positioning data No. setting
value
Monitor whether the speed is being limited
[Md.39] In speed limit flag
Monitor whether the speed is being changed
[Md.40] In speed change processing flag
Monitor the remaining number of repetitions (special start)
[Md.41] Special start repetition counter
Monitor the remaining number of repetitions (control system)
[Md.42] Control system repetition counter
Monitor the "start data" point currently being executed
[Md.43] Start data pointer being executed
Monitor the "positioning data No." currently being executed
[Md.44] Positioning data No. being executed
Monitor the block No.
[Md.45] Block No. being executed
Monitor the "positioning data No." executed last
[Md.46] Last executed positioning data No.
Monitor the positioning data currently being executed
[Md.47] Positioning data being executed
Monitor switching from the constant speed status or acceleration status to the deceleration status during
position control whose operation pattern is "Positioning complete"
[Md.48] Deceleration start flag
Monitor the carrying over movement amount which exceeds "[Pr.123] Manual pulse generator speed limit
value".
[Md.62] Amount of the manual pulser driving
carrying over movement
Monitor the distance that travels to zero point after stop once at home position return.
[Md.100] Home position return re-travel value
Monitor the command torque at torque control mode or continuous operation to torque control mode in the
speed-torque control.
[Md.123] Torque during command
Monitor the switching status of control mode.
[Md.124] Control mode switching status
Monitor the positioning data analysis status.
[Md.503] Pre-reading data analysis status
Summary of Contents for RD77MS16
Page 1: ...MELSEC iQ R Simple Motion Module User s Manual Application RD77MS2 RD77MS4 RD77MS8 RD77MS16 ...
Page 2: ......
Page 316: ...314 9 COMMON FUNCTIONS 9 4 External Input Signal Select Function Program example ...
Page 317: ...9 COMMON FUNCTIONS 9 4 External Input Signal Select Function 315 9 ...
Page 575: ...13 PROGRAMMING 13 4 Positioning Program Examples 573 13 Error reset program Axis stop program ...
Page 643: ......