12 DATA USED FOR POSITIONING CONTROL
12.9 Memory Configuration and Data Process
551
12
(8) Reading data from buffer memory/internal memory to the engineering tool
The following transmission processes are carried out with the [Read from module (Read from RD77MS)] from the engineering
tool.
• The "parameters", "positioning data (No. 1 to 600)", "block start data (No. 7000 to 7004)" and "servo parameter" in the
buffer memory/internal memory area are transmitted to the engineering tool via the CPU module.
The following transmission processes are carried out with the [monitor] from the engineering tool.
• The "monitor data" in the buffer memory area is transmitted to the engineering tool via the CPU module.
(9) Writing data from the engineering tool to buffer memory/internal memory
The following transmission processes are carried out with the [Write to module (Write to RD77MS)] from the engineering tool.
• The "parameters", "positioning data (No. 1 to 600)", "block start data (No. 7000 to 7004)" and "servo parameter" in the
engineering tool are transmitted to the buffer memory/internal memory via the CPU module.
At this time, when [Flash ROM automatic write] is set with the engineering tool, the transmission processes indicated with "(7)
Flash ROM write" are carried out.
Summary of Contents for RD77MS16
Page 1: ...MELSEC iQ R Simple Motion Module User s Manual Application RD77MS2 RD77MS4 RD77MS8 RD77MS16 ...
Page 2: ......
Page 316: ...314 9 COMMON FUNCTIONS 9 4 External Input Signal Select Function Program example ...
Page 317: ...9 COMMON FUNCTIONS 9 4 External Input Signal Select Function 315 9 ...
Page 575: ...13 PROGRAMMING 13 4 Positioning Program Examples 573 13 Error reset program Axis stop program ...
Page 643: ......