374
12 DATA USED FOR POSITIONING CONTROL
12.1 Types of Data
Expansion control
: Always set,
: Set as required ("
" when not required),
: Setting restricted,
: Setting not possible
: Setting not required (The setting value is invalid. When the value is the default value or within the setting range, there is no
problem.)
Positioning parameter
Expansion control
Speed-torque control
Basic parameters 1
[Pr.1] Unit setting
[Pr.2] Number of pulses per rotation (AP) (Unit: pulse)
[Pr.3] Movement amount per rotation (AL)
[Pr.4] Unit magnification (AM)
[Pr.7] Bias speed at start
Basic parameters 2
[Pr.8] Speed limit value
[Pr.9] Acceleration time 0
[Pr.10] Deceleration time 0
Detailed parameters 1
[Pr.11] Backlash compensation amount
[Pr.12] Software stroke limit upper limit value
[Pr.13] Software stroke limit lower limit value
[Pr.14] Software stroke limit selection
[Pr.15] Software stroke limit valid/invalid setting
[Pr.16] Command in-position width
[Pr.17] Torque limit setting value
[Pr.18] M code ON signal output timing
[Pr.19] Speed switching mode
[Pr.20] Interpolation speed designation method
[Pr.21] Current feed value during speed control
[Pr.22] Input signal logic selection
[Pr.81] Speed-position function selection
[Pr.116] FLS signal selection
[Pr.117] RLS signal selection
[Pr.118] DOG signal selection
[Pr.119] STOP signal selection
Summary of Contents for RD77MS16
Page 1: ...MELSEC iQ R Simple Motion Module User s Manual Application RD77MS2 RD77MS4 RD77MS8 RD77MS16 ...
Page 2: ......
Page 316: ...314 9 COMMON FUNCTIONS 9 4 External Input Signal Select Function Program example ...
Page 317: ...9 COMMON FUNCTIONS 9 4 External Input Signal Select Function 315 9 ...
Page 575: ...13 PROGRAMMING 13 4 Positioning Program Examples 573 13 Error reset program Axis stop program ...
Page 643: ......