526
12 DATA USED FOR POSITIONING CONTROL
12.8 Control Data
[Cd.43] Simultaneous starting axis
• Set the number of simultaneous starting axes and target axis. When "2" is set to the number of simultaneous starting axes,
set the target axis No. to the simultaneous starting axis No. 1. When "3" is set to the number of simultaneous starting axes,
set the target axis No. to the simultaneous starting axis No.1 and 2. When "4" is set to the number of simultaneous starting
axes, set the target axis No. to the simultaneous starting axis No.1 to 3.
• When the same axis No. or axis No. of own axis is set to the multiple simultaneous starting axis No, or the value outside the
range is set to the number of simultaneous starting axes, the error "Error before simultaneous start" (error code: 1990H,
1991H) occurs and the operation is not executed.
Do not set the simultaneous starting axis No.2 and 3 for 2-axis interpolation, and do not set the simultaneous
starting axis No.3 for 3-axis interpolation. The setting value is ignored.
Fetch cycle: At start
■
Setting value
• Set with a hexadecimal.
• Buffer memory address
Refer to the following for the buffer memory address in this area.
Setting
value
H
Simultaneous starting axis No.1
00 to 0F: Axis 1 to Axis 16
Simultaneous starting axis No.2
00 to 0F: Axis 1 to Axis 16
Low-order buffer memory
Simultaneous starting axis No.3
00 to 0F: Axis 1 to Axis 16
Number of simultaneous starting axes
2 to 4: 2 axes to 4 axes
Setting
value
H
High-order buffer memory
Summary of Contents for RD77MS16
Page 1: ...MELSEC iQ R Simple Motion Module User s Manual Application RD77MS2 RD77MS4 RD77MS8 RD77MS16 ...
Page 2: ......
Page 316: ...314 9 COMMON FUNCTIONS 9 4 External Input Signal Select Function Program example ...
Page 317: ...9 COMMON FUNCTIONS 9 4 External Input Signal Select Function 315 9 ...
Page 575: ...13 PROGRAMMING 13 4 Positioning Program Examples 573 13 Error reset program Axis stop program ...
Page 643: ......